802483
5
Zoom out
Zoom in
Previous page
1/7
Next page
GBW 300
NGW 300 / LGW 300
Operating and
maintenance instructions
Standard timer
General
The standard digital timer enables you
to preset the start of the heater
operation up to 7 days in advance.
It is possible to program 3 different
starting times, only one of which can be
activated.
The standard digital timer features a
wake-up alarm function.
When the ignition is switched on, the
timer displays the current time and the
day of the week. When the heater is
switched on, the display and the buttons
are illuminated.
After the power supply has been
connected, all symbols on the display
Operation
The timer can be operated in that all
flashing symbols can be adjusted by
means of the and buttons. If the
buttons are not pressed within 5
seconds, the time displayed will be
stored. If the and buttons are
pressed for more than 2 seconds, the fast
time-setting mode is activated.
If the ignition is switched off while the
heater is operating in the continuous
mode, the remaining operating time of
15 minutes is displayed and the heater
continues to operate for this period of
time.
Switching the heater on
Manually: by pressing the button
(continuous heating mode)
Automatically: by programming the
heater starting time
Switching the heater off
Manually: by pressing the button
Automatically: by programming the
operating time
With the heater running: by program-
ming the remaining operating time
Setting time/day of the week
Press the button for more than 2
seconds - time of the day is flashing -
and set the clock using the and
buttons. Day of the week is flashing -
adjust the day of the week.
Viewing the time
With the ignition switched off: press
the button
Programming heater starting time
Press the button - the memory
location is flashing - using the and
buttons, set the heater starting time.
Day of the week is flashing - set the day
of the week. By repeatedly pressing the
button, memory locations 2 and 3
can be programmed or the time display
mode can be reached.
Recalling/erasing preset times
Repeatedly press the button until the
desired memory location is displayed. To
erase the preset time, press the
button several times until the time of
the day is displayed instead of the
memory location.
Programming duration of operating time
The heater must be switched off. Press
the button for 3 seconds - operating
time is flashing - and set the desired
operating time (10 to 120 minutes) using
the and buttons.
Setting the remaining operating time
Set the desired remaining operating
time (1 to 120 minutes) using the and
buttons. The remaining operating
time refers to the time the heater still
continues to remain in operation. It can
only be changed while the heater is in
operation and the ignition switched off.
Setting the wake-up time
A wake-up time can only be program-
med on the standard digital timer. The
wake-up time is not bound to a specific
day of the week. Repeatedly press the
button until the bell symbol appears
on the display. Set the desired wake-up
time using the and buttons. The
alarm clock turns off after 5 minutes or
when one of the buttons is pressed.
Remote control
Possible by means of an optional
external "instant heating" button
Recalling/erasing the wake-up time
Repeatedly press the button until the
bell symbol appears on the display -
read off wake-up time. To erase the
wake-up time: press the button until
the bell symbol is no longer visible on
the display.
day of the week heater on” indicator
forward
standard timer
instant
heating
reverseprogram
selection
time
alarm indicator
memory location
time display
2
MO
will flash. The current time and weekday
must be set.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto LGW 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto LGW 300 in the language / languages: English as an attachment in your email.

The manual is 0.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto LGW 300

Webasto LGW 300 User Manual - German - 7 pages

Webasto LGW 300 User Manual - French - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info