634254
8
Zoom out
Zoom in
Previous page
1/38
Next page
DBW 2010
DBW 2020
DBW 300
Operating Instructions
Coolant Heaters
North American Headquarters
3333 John Conley Drive
Lapeer, MI 48446
Phone (810) 245-2400
Toll-free (800) HEATER-1
Fax (810) 664-7720
Canadian Operations
Toll-free (800) 667-8900
Website: www.webasto.com
Rev. 11/00 699540 (English)
I
WEBASTO DBW SERIES HEATERS
Introduction
Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General Safety Regulations and Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Meaning of Warnings, Cautions and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Coolant Heater DBW 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Coolant Heaters DBW 2020 / 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Instructions
Operating your Webasto DBW Series Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Switching On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Switching Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Engine Preheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation with 7-Day Digital Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Setting the Digital Timer (Models 1529 & 1531) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7-Day Digital Timer Programming and Operating Instructions (Models 1529 & 1531) . . . . . . 14
Operation with 7-Day Electronic Timer Model CDN-1224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Timer Operation Modes (Model CDN-1224) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CONTENTS
II
WEBASTO DBW SERIES HEATERS CONTENTS
Dip Switch Programming (Model CDN-1224) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Timer Operation (Model CDN-1224) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Maintenance
Maintenance of the Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Basic Troubleshooting
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Malfunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Malfunction Identification - DBW Series Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Sequence of Events - DBW Series Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Technical Data
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Heater Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
U 4810 and U 4846 Coolant Pump Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
U 4814, U 4851 and U 4852 Coolant Pump Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
1
WEBASTO DBW SERIES HEATERS INTRODUCTION
Introduction
Important Information
The heater must be installed according to the “Installation Instructions” and must be examined by an officially
recognized, Webasto authorized installation/ servicing facility.
When the heater is installed in vehicles used for the transportation of dangerous or inflammable goods, or in
boats, the appropriate regulations must be observed.
Webasto Thermosystems, Inc. does not recommend the installation and servicing of Webasto products by
untrained, unauthorized personnel or end-users.
Installations and servicing of Webasto products by untrained, unauthorized personnel and end-users will release
Webasto Thermosystems, Inc. and Webasto authorized distributors, dealers and personnel from responsibility for
damage to Webasto product or collateral property and personal injury.
Any use, operation, installation, modification or application of the product not described in Webasto manuals, or
subjecting the product to extreme or unusual conditions beyond the limits of specified performance characteristics
is misuse of the product.
Failure to comply with all operation, installation, and servicing instructions is a misuse of Webasto product.
The same applies for repairs without using genuine Webasto service parts. This will void the coolant heaters
“Official Marks of Conformity.”
In the vicinity of the coolant heater, a temperature of 185 °F (85 °C) must not be exceeded under any
circumstances (e.g. during body paint work). A violation of this temperature limit may cause permanent damage
to the electronics.
2
INTRODUCTIONWEBASTO DBW SERIES HEATERS
WARNING
Due to the danger of poisoning and suffocation, the heater must not be operated in enclosed areas, such as garages
or workshops, without an exhaust venting system, not even if the start-up is activated by the timer or remote start
device.
At filling stations and fuel depots the heater must be switched off as there is a potential danger of explosions.
Where flammable fumes or dust may build up (e.g. in the vicinity of fuel, coal, wood, cereal grain deposits or similar
situations) the heater must be switched off to prevent explosions.
When checking the coolant level, proceed in accordance with the vehicle manufacturers instructions.
The coolant in the heating circuit of the heater must contain a minimum of 10% of a quality brand glycol based
anti-freeze.
The pressure setting of the coolant filler cap should be between 0.4 and 2 bar (6 p.s.i. and 28 p.s.i.).
The coolant heater may only be operated within the specified operating voltage range designated by type.
The coolant heater may only be operated with the specified fuel (Diesel 1, Diesel 2, Arctic grade, Kerosene and
certain military spec. fuels).
The operational state of the heater, i.e. an indication “On” or “Off”, must be clearly visible to the operator.
If electrical welding is to be done on the vehicle, the main positive and negative feed cables should be
disconnected from the battery and securely connected to the chassis. This is necessary to protect the electronic
control unit from voltage surges.
3
WEBASTO DBW SERIES HEATERS INTRODUCTION
General Safety Regulations and Information
The general safety regulations for the prevention of accidents and relevant operating safety instructions must be
observed at all times. The specific safety regulations applicable to this manual are highlighted in the individual
chapters by Warnings, Cautions and Notes.
Meaning of Warnings, Cautions, and Notes
Warnings, Cautions and Notes in this manual have the following meaning:
NOTE:
This heading is used to highlight and draw specific attention to information.
CAUTION
This heading is used to highlight that non-compliance with instructions or procedures may cause damage to
equipment.
WARNING
This heading is used to highlight that non-compliance with instructions or procedures may cause injuries or lethal
accidents to personnel.
4
INTRODUCTIONWEBASTO DBW SERIES HEATERS
WEBASTO DBW SERIES HEATERS DESCRIPTION
General Description
1 Electronic control unit
2 Motor
3 Electronic ignition coil
4 Coupler
5 Combustion air fan
6 Fuel solenoid valve
7 Electrode holder
8 Coolant outlet
9 Coolant inlet
10 Ignition electrodes
11 Fuel nozzle
12 Overheat fuse (white wires)
13 Control thermostat
14 Temperature limiter
15 Heat exchangers
16 Combustion chamber
17 Combustion air swirler
18 Exhaust pipe
19 Flame detector
20 Fuel pump
21 Fuel supply/ return pipes
22 Combustion air adjusting shutter
23 Fuel pump drive gearing
24 Nozzle pre-heater
25 Preheat thermostat (blue & green wires)
26 Air bleed screw
Fig. 1: Major Components of the DBW 2010 Coolant Heater
5
12345
23
6
25
7
24
81011 12
13
14
9
26
22 21 20 19 18 17 16 15
Coolant Heater DBW 2010
DESCRIPTIONWEBASTO DBW SERIES HEATERS
6
1 Electronic control unit
2 Motor
3 Electronic ignition coil
4 Coupler
5 Combustion air fan
6 Fuel solenoid valve
7 Electrode holder
8 Coolant inlet
9 Ignition electrodes
10 Fuel nozzle
11 Overheat fuse (white wires)
12 Control thermostat
13 Temperature limiter
14 Coolant outlet
15 Heat exchangers
16 Combustion chamber
17 Combustion air swirler
18 Exhaust pipe
19 Flame detector
20 Fuel pump
21 Fuel supply/ return pipes
22 Combustion air adjusting shutter
Fig. 2: Major Components of the DBW 2020 / 300 Coolant Heaters
1 2 3 4 5 6 7 8 10 11 12 13 149
22 21 20 19 18 17 16 15
Coolant Heaters DBW 2020 / 300
OPERATING INSTRUCTIONS
Operating Instructions
Operating your Webasto DBW Series Heater
WARNING
Due to the risk of carbon monoxide poisoning and asphyxiation, the heater must never be operated in closed spaces
such as garages and workshops without adequate exhaust extraction.
WARNING
Due to the risk of fire or explosion, the heater must be switched off while refueling and at fueling stations.
WARNING
Due to the risk of explosion, the heater must never be operated in areas where explosive materials, fumes or dusts
may be present.
7
WEBASTO DBW SERIES HEATERS
OPERATING INSTRUCTIONS
Heater Start-up Sequence:
Upon switching on, an operating indicator light will illuminate.
The combustion air fan, fuel pump and circulation pump start operation. (If fitted and temperature is < 0 °C (< 32 °F)
nozzle preheating is also activated).
After approximately 15 seconds the fuel solenoid valve opens allowing fuel to flow to the nozzle where it is atomized
and sprayed into the combustion chamber. At the same time, a high voltage ignition spark is generated at the
electrode tips simultaneously igniting the fuel air mixture. A photo control device detects a flame in the combustion
chamber and deactivates the ignition system (combustion process is self-sustaining). At this point the heater is
working and producing heat.
The Webasto heater will cycle on and off until:
1. System coolant reaches operating temperature.
2. The Webasto heater is switched off.
3. Time has elapsed on the timer.
4. The vehicle battery voltage drops below 10.5V for 12 volt systems or 20.0V for 24 volt systems.
5. The Webasto heater runs out of fuel.
6. A fault lock out occurs, indicated by the operating indicator light being off during the cool down cycle (as would
happen during an overheat situation.
NOTE:
If the heater is switched on while the engine is at operating temperatures above 140 °F (60 °C) for orange and white
wire thermostat or 155 °F (68 °C) for red and green wire thermostat, only the operation indicator and the coolant
circulation pump will be activated. Depending on the type of thermostat installed, the engine coolant temperature
must fall below 140 °F (60 °C) or 155 °F (68 °C) at the heater before the heater will begin heating operation.
9
WEBASTO DBW SERIES HEATERS
WEBASTO DBW SERIES HEATERS
Switching Off
When heating is no longer required, switch the Webasto heater off. The fuel solenoid valve interrupts the fuel supply
and combustion stops. The indicator light turns off. The Combustion air fan and the water pump continue operation
for approximately 150 seconds (after-run cycle) purging the combustion chamber of any fumes and cooling the
heater.
Engine Preheating
1. Set the timer 10 min. to 120 min. before you want to start the engine. The heater will start up at the set time.
(See timer operating instructions). Or switch the toggle switch or “Instant On” switch on your timer in the vehicle
dash to “On”. The heater will start up.
2. When the run time has elapsed on your timer or engine preheating is no longer required, switch the Webasto
heater “Off”. The heater will begin the after-run (cool-down) cycle.
NOTE:
Switching the Webasto heater on during the cool-down (after-run cycle) period is allowed. The heater will revert to
normal operational mode.
NOTE:
Make sure all coolant and cab heater valves are open before operating the heater in the preheat mode.
10
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
The digital timer with 3 time settings permits the
Webasto heater to be switched on and off instantly, or
automatically at 3 programmable starting times.
The operating time of the heater can be pre-selected.
It is possible to program 3 different heating times
according to your individual needs.
Only one preset starting time can be activated at any
one time. When the ignition is switched on, the
current time of the day and the day of the week are
displayed.
When the heater is in operation, the display and the
buttons of the timer are illuminated.
11
WEBASTO DBW SERIES HEATERS
Operation with 7-Day Digital Timer (Model 1529 Shown)
WEBASTO DBW SERIES HEATERS
7-Day Digital Timer Programming and Operating Instructions (Models 1529 & 1531)
Setting the time and
day of the week
Viewing the time
Switching heater on
for instant heater
operation
Press the button for more than 2 seconds. Time display flashes.
Press the or button to set time of day. Wait 5 seconds. Time is now stored.
Day of week flashes.
Press or button to set day of week. Wait 5 seconds. Day of week is now stored.
With ignition “ON”:
Continuous display of current time and day of the week.
With ignition “OFF”:
Briefly press button. Display of current time and weekday appears for 5 seconds.
With ignition “ON”:
Press button. Heater is switched on (continuous heating) and continues to operate until
button is pressed again or ignition is switched off.
With ignition “OFF”:
Press button. Heater is switched on for the preset operating time
(the factory-set heater operating duration is 60 minutes).
Switching the
heater off
Press button. Heater begins cool-down (after-run) cycle and is switched off thereafter.
14
OPERATING INSTRUCTIONS
Table 1: Digital Timer Instructions
16
OPERATING INSTRUCTIONSWEBASTO DBW SERIES HEATERS
The 7-Day Electronic Timer Model CDN-1224 permits the Webasto heater
to be switched on and off instantly, or automatically.
The timer allows for 1 preset start time once within a 24 hour period on
any one day up to 7 days in advance.
The current time and weekday must be preset before any other
programming features can be accomplished.
The 7-Day Electronic Timer is designed to operate on both 12 and 24 volt
systems.
Operational characteristics of both timer and heater can be tailored to the
requirements of the heating application by pre-programming of the timer.
This is normally done at the time of installation. Four dip switches located on the back panel of the timer are provided
for changing the operational characteristics of the timer. These settings can be revised at any time should your
heating requirements change.
Operation with 7-Day Electronic Timer Model CDN-1224
CAUTION
Timer requires dismounting and disconnecting of power source before revising dip switch settings.
Set Clock
Set Timer
Set
Heater
on/off
manual
Timer
on/off
Display
Hour
Day
Minute
SM
TWT F
S
P
T
H
12:00
For complete timer installation and operation instructions, refer to the 7-Day Electronic Timer Model CDN-1224
Operating Instructions manual available from your Webasto agent under part number 907111.
17
WEBASTO DBW SERIES HEATERS OPERATING INSTRUCTIONS
Timer Operation Modes (Model CDN-1224)
Truck or Bus Operation
By flipping one of the dip switches on the back of the unit, the timer can be set for either truck or bus operation. The
tables shown below illustrates the timing sequence associated with operation in either of these modes.
Bus Application
Ignition wire is connected and dip switch #3 is in bus mode.
Whether the heater is turned on manually or automatically, it will stay on until the timer duration ends. Except, when
the heater is turned on manually while the bus is running (ignition key turned on), the heater will shut off when the
ignition key is turned off, or the heater on/off button is pressed.
Truck Application for Preheat Mode Only
Ignition wire is disconnected and dip switch #3 is in truck mode.
Pre-set Mode Heater on Timer duration ends Heater turns off after time duration ends
Manual Mode Heater on Timer duration ends Heater turns off after time duration ends
Truck Application for Preheat and Sleeping Modes
Ignition wire is always live and dip switch #3 is in truck mode.
Pre-set Mode Heater on Timer duration ends Heater turns off after time duration ends
Manual Mode Heater on Timer duration ends Heater stays on until turned off manually
18
OPERATING INSTRUCTIONSWEBASTO DBW SERIES HEATERS
Dip Switch programming
(Model CDN-1224)
Prior to installing the timer, all dip switches must be set
to the requirements of your application.
The dip switches allow for setting the clock in either
AM/PM mode or 24 hour (military) mode. Also included
is the ability to select the desired heater run time of 30,
60, 90 or 120 minutes.
Dip switch settings are accessed through a cut out on
the rear panel of the timer.
NOTE:
Dip switch settings are to be selected PRIOR to connection of power source and programming of all other timer
functions.
Fig. 4: Rear Panel of Timer
Dip Switch
Location
1 2 3 4
OPEN
19
WEBASTO DBW SERIES HEATERS OPERATING INSTRUCTIONS
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
Switch 1 & 2 control timer on duration.
30 Minute
60 Minute
90 Minute
120 Minute
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
Switch 3 controls truck vs. bus operation.
Bus Mode
Truck Mode
Switch 4 controls 12 vs. 24 hour clock.
12 hour clock
24 hour clock
Default settings for new timers are:
Truck - 60 minute operation time, 12 hour clock
Bus - 60 minute operation time, 12 hour clock
20
OPERATING INSTRUCTIONSWEBASTO DBW SERIES HEATERS
Set Clock
Set Timer
Set
Heater
on/off
manual
Timer
on/off
Display
Hour
Day
Minute
SM
TWT F
S
P
T
H
12:00
1
2
3
4
5
6
Setting the Electronic Timer
(Model CDN-1224)
1 Time Display
2 Heater on/off indicator LED (green)
3 Timer active status LED (yellow)
4 Clock time status LED (red)
This LED will be on during PM time when AM/PM
dip switch setting is selected
5 Days of the week LED’s (red)
6 Function buttons
Fig. 5: 7-Day Electronic Timer Model CDN-1224
21
WEBASTO DBW SERIES HEATERS OPERATING INSTRUCTIONS
Clock Programming (Present Time and Day)
Depress buttons ‘Set’ and ‘Display’ simultaneously to start programming
NOTE: Time display will begin to flash.
Depress button ‘Day’ to select day of week.
Depress button ‘Hour’ to select correct hour.
NOTE: If the dip switch setting is in the AM/PM mode, the red PM LED will respond.
Depress button ‘Minute’ to select correct minute.
Depress button ‘Set’ to end timer programming.
NOTE: If ‘Set’ button is not depressed within 15 seconds, programming function
will end automatically.
Heater
on/off
manual
Set
Display
Set
Timer
on/off
Display
Minute
Minute
Hour
Day
AND
24
OPERATING INSTRUCTIONSWEBASTO DBW SERIES HEATERS
25
WEBASTO DBW SERIES HEATERS MAINTENANCE
Maintenance of the Heater
To ensure functional reliability of the heater the following maintenance must be performed:
check combustion air inlet and exhaust outlet for contamination and clean as required.
outside the heating season the heater should be operated with the vehicle engine cold approximately every four
weeks for 10 minutes setting the heating system to "warm" and opening all appropriate coolant flow control
valves. This avoids difficulties in the startup at the beginning of the heating season and prolongs heater motor
and bearing life.
after replacing the coolant of the vehicle engine ensure proper bleeding of the heater after bleeding the vehicle
cooling system. Start the vehicle engine and turn OEM heater system on in full heat mode. Switch on heater
circulation pump (if separate switch is available) or operate heater for 5 seconds to run circulation pump using
rundown cycle. Repeat procedure as required until warm air comes out of heating ducts. Replenish coolant to
manufacturer's instructions if level is low.
before the heating season (point of time when weather conditions cause increased use of equipment) the fuel
filter or filter cartridge must be replaced to prevent malfunctions.
the heater should be checked on regular intervals by a Webasto service agent, the latest before the beginning of
the heating season.
28
BASIC TROUBLESHOOTINGWEBASTO DBW SERIES HEATERS
Malfunctions
The DBW Series of coolant heaters are designed with automatic, self-monitoring systems that will shut the heater off
in the event of a problem.
The heater will switch itself off automatically if combustion does not start after the heater has been switched on, or if
the flame goes out, or if the heater overheats. The operation indicator light will go out to signify a problem.
The following steps can be taken to determine and correct obvious problems.
If the operation indicator light does not come on at the same time as the heater is switched on, check and, if
necessary, replace fuse (F2). If the operation indicator light comes on when the heater is switched on, but goes out
after about 30 seconds, check and, if necessary, replace fuse (F3).
If overheating has occurred, locate and correct the problem. On the DBW 2010 Arctic, DBW 2020 and DBW 300
series heaters, it may be necessary to replace the overheat melt fuse located under the thermostat cover on top of
the heater. The fuse can be identified by the two white wires protruding from its top. The fuse is screwed hand tight
into a dry well plug. Do not over tighten the fuse when replacing. On all other DBW 2010 heaters not equipped with
an overheat fuse, simply correct the cause of overheating and allow the heater to cool down.
If a lock-out condition occurs due to a malfunction, this condition can be cleared and the control unit reset by
switching the heater off and switching it back on again. If the heater goes to lock-out once again after correcting all
obvious problems, consult your nearest Webasto Service Station.
NOTE:
In most heater models, the fuses referred to in the above paragraph can be located on the back wall of the heater
enclosure or are tray. Some models may also utilize a 30 amp. main fuse at the battery connection.
30
BASIC TROUBLESHOOTINGWEBASTO DBW SERIES HEATERS BASIC TROUBLESHOOTING
Sequence of Events - DBW Series Heaters
The normal sequence of events illustrated here may be used in conjunction
with the malfunction identification table to help determine heater problems.
NOTE:
After the correction of a
malfunction, a functional
test must always be
performed with the heater
installed in the vehicle in
its operational position.
Table 3: Sequence of Events
WEBASTO DBW SERIES HEATERS TECHNICAL DATA
Technical Data
General Information
Where no threshold values are specified,
technical data are understood to include
standard tolerances for heater units of ± 10%
at ambient temperature of + 20 °C (+ 68 °F)
and at nominal voltage.
Electrical components:
Control unit, fan and circulation pump
motors, solenoid valve, igniter box, heater
cartridge, nozzle pre-heater and timer are
voltage sensitive components. Temperature
limiter, overheat fuse, control thermostat,
flame sensor and switches are voltage
independent components.
Heater DBW 2010 DBW 2020 DBW 300
Mark of conformity ~ S 129 ~ S 136 ~ S 164
Heater design principle High pressure fuel atomizing nozzle
Heat output kW/h (BTU/h) 13.1 (45,000) 23.3 (80,000) 30 (104,000)
Fuel Diesel #1, Diesel #2, Arctic grade and Kerosene
Maximum fuel consumption l/h (US gal/h) 1.5 (0.4) 3.0 (0.79) 4.0 (1.05)
Rated nominal voltage V 12 or 24
Operating voltage V 10 ... 14 or 20 ... 28
Nominal power consumption W 60 120 130
(without circulation pump)
Permissible operating ambient °C (°F) - 40 ... + 60 (- 40 … + 140)
temperature range
(heater, control unit, circulation pump)
Permissible storage temperature °C (°F) + 85 max. (+ 185)
Permissible operating pressure bar (psi) 0.4 ... 2.0 (06 … 29)
of coolant system
Minimum capacity of circuit l (US. Gal) 10.00 (2.64)
CO
2
in exhaust at nominal voltage Vol.-% 10.5 ... 11.0
CO in exhaust at nominal voltage Vol.-% 0.2 maximum
Dimensions of heater length mm (in.) 584 (23”) 680 (26-23/32”)
width mm (in.) 205 (8-1/6”) 240 (9-1/2”)
height mm (in.) 228 (10”) 279 (10-29/32”)
Weight (without enclosure) 15 kg (33 lbs.) 22 kg (48 lbs.)
Heater Data
Refer to adjacent table
Table 4: Heater Data
31
WEBASTO DBW SERIES HEATERS TECHNICAL DATA
Coolant Circulation Pump
Volume flow l/h (US. Gal/min)
Nominal voltage V
Operating voltage range V
Nominal power consumption W
Dimensions of length
coolant circulation pump width
height
Hose connection O.D.
Weight kg (lb.)
U 4814
5200 (22.9) @ 0.15 bar
12 or 24
10 ... 14 or 20 ... 28
104
221 mm (8.7 in.)
100 mm (3.94 in.)
105 mm (4.14 in.)
38.0 mm (1.5 in.)
2.1 (4.63)
U 4851 & U 4852
6000 (26.4) @ 0.4 bar
24
18 ... 32
209
285 mm (11.22 in.)
115 mm (4.52 in.)
110 mm (4.33 in.)
38.0 mm (1.5 in.)
2.7 (5.95)
U 4814, U 4851 and U 4852 Coolant Pump Data
Table 6: U 4810 & U 4846 Coolant Pump Data
NOTE:
The allocation of circulation pumps to heater units must be in accordance with coolant resistances.
Recommended coolant circulation pumps for DBW 2020 and DBW 300 heaters.
33
34
NOTESWEBASTO DBW SERIES HEATERS
NOTES
North American Headquarters
3333 John Conley Drive
Lapeer, MI 48446
Phone (810) 245-2400
Toll-free (800) HEATER-1
Fax (810) 664-7720
Canadian Operations
Toll-free (800) 667-8900
Website: www.webasto.com
Rev. 11/00 699540 (English)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto DBW 2020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto DBW 2020 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto DBW 2020

Webasto DBW 2020 User Manual - English - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info