Heater cuts out automatically
Black smoke is emitted from the heater
Cause
Cause
Remedy
Remedy
Troubleshooting Error code output on combination timer or control element
NOTE for ADR mode only:
!
If an error occurs, first check the fuse and plug connections to ensure that they are in
perfect condition and connected correctly.
If the action described below does not rectify the error, have the heater checked by
Webasto-trained personnel.
No start (after 2 attempts to start)
Flame failure (at least > 5)
Undervoltage or overvoltage
Premature flame recognition
Flame monitor interrupt or
flame sensor short-circuit
Temperature sensor interrupt or
temperature sensor short circuit
Metering pump short circuit
Fan motor interrupt or
fan motor short circuit or
fan motor overload or blocked
Glow plug interrupt or glow plug short circuit
Overheating
F01
F02
F03
F04
F06
F07
F08
F09
F10
F05
If the system is fitted with a combination timer, when an error occurs an error code is
output on the timer's display until the heater has been rectified.
If the system is fitted with a control element, when an error occurs an error code is output
by the indicator/error code display flashing. After a burst of fast flashes the error code will
be output by a sequence of long flashes, the number of which is shown in the table
below. The error code will continue until the heater is reset.
Meaning of error code
After an ADR cut-out or the application of operating voltage by switching on the main
vehicle switch and setting the control element to ”ON” the control unit will be set to
the “Fault cut-out” position.
Before the heater can be restarted the control element must be set to “OFF” or the
immediate heat button on the combination or standard timer must be pressed.
No combustion after start
and repeat start
Flame extinguishes during
operation
Heater overheats
Indicator flashes
Vehicle voltage too low
Combustion air and/or
exhaust system blocked
Switch the heater off (wait at least 2 seconds) and
then on again
Switch the heater off (wait at least 2 seconds) and
then on again
Check that the hot air can flow freely.
Allow the heater to cool.
Switch the heater off (wait at least 2 seconds) and
then on again
Charge battery
Switch the heater off (wait at least 2 seconds) and
then on again
Check combustion air and exhaust system for
blockages
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto AIRTOP 2000 -S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto AIRTOP 2000 -S in the language / languages: English as an attachment in your email.

The manual is 0.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto AIRTOP 2000 -S

Webasto AIRTOP 2000 -S User Manual - German - 4 pages

Webasto AIRTOP 2000 -S User Manual - Dutch - 25 pages

Webasto AIRTOP 2000 -S User Manual - French - 4 pages

Webasto AIRTOP 2000 -S User Manual - Italian - 4 pages

Webasto AIRTOP 2000 -S User Manual - Spanish - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info