Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: info@aktobis.de
Please switch off the unit immediately and disconnect it from the mains/power supply if anything
seems to be wrong !!! In this case, please contact a specialist and do not attempt to repair the
unit yourself !!!
Examples: Fan does not run during operation, fuse has blown or compressor rattles loudly.
Important operating and safety instructions regarding the refrigerant R290 in this unit:
(Read these instructions carefully and observe them before using the unit !)
The refrigerant R290 complies with the European environmental directives !
The unit operates with the refrigerant R290. This refrigerant is highly flammable and
explosive if the safety instructions are not observed!
The unit contains 0.125 kg of refrigerant R290 - the maximum permitted charge of refrigerant
R290 for dehumidifiers is 0.3 kg !
The minimum air circulation is 160 m³/h !
The appliance must be stored in a room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance or an operating electric heater).
Protect the unit and especially the parts installed inside from damage or flames/heat !
Please note that the refrigerant is odourless and therefore a leak cannot be detected
immediately by an emerging odour !
If refrigerant leaks, it may ignite or explode, especially in poorly ventilated rooms in
conjunction with high heat, sparks or flames !
Make sure that the outlet of the exhaust air is always ensured and not obstructed by other
objects !
Set-up, operation and storage of the unit should take place in a room with a minimum size of
4 m2 !
Pack the unit carefully when you are no longer using it to protect it from damage ! Be careful
when storing the unit to avoid mechanical faults.
When cleaning, proceed strictly according to the manufacturer's instructions and do not use
any additional heat sources to possibly accelerate the defrosting process of the appliance!
Never work on the cooling circuit or parts containing refrigerant yourself !
Only persons authorised and certified by an accredited agency to handle refrigerants should
work on the refrigerant circuit.
If the mains lead of this appliance is damaged, it must be replaced by the manufacturer or its
after-sales service or a similarly qualified person in order to avoid hazards.
The unit must be installed according to the national installation regulations.
Do not use any objects, except those permitted by the manufacturer, to accelerate the
defrosting process.
Do not drill or burn.