Press the filter button to activate the water filtration. The green indicator light will
turn on when the filtration system is activated. Please note that filters should be
changed every 7 days, or until they become discolored.
Note:
- If bubble function is on, the filtration can’t be activated.
Press the heating button to activate water heating and filtering system at the
same time. The green indicator light of filter and red indicator light of heating will
turn on at same time
The pump does not stop heating until the current water temperature reaches the
set temperature; and the heating system will restart after the current water
temperature drops 2°C below the set temperature automatically.
Maximum heating temperature: 42°C (108°F)
Important:
After 150 cumulative hours of filtration operations, an audible alarm will
sound and the LCD display will show the characters CHG, followed by FIL,
to remind you to change or clean the filter. You can hold the filtering button
5 seconds to turn off the buzzing. The filtering system will turn off, you can
press the button to activate the filtering system again.
Note:
-
With the heating system starting, the filtration system will start working together.
-
After turning off the heating system, the filtration system will still work.
-
If the bubble function is active, the filtration and heating functions cannot be activated.
4.3. Spa cover and security
After each use, the control panel must be locked and the spa must be covered with
its top cover and it must be attached to the base protector with the safety buckles.
Each safety buckle has a lock system; To close the buckle, put the latch in an up
position which locks the buckle, Put the latch in a down position to unlock the
buckle.
The top cover retains the heat from the water and secures the spa.
5.1. Water maintenance
WARNING: Bad spa water quality can harm your health.
Depending on the frequency and conditions of use:
- The filter cartridge should be regularly cleaned / replaced every 150 hours max.
- The filter cartridge should be replaced every 150 hours unless cleanable.
- The spa water should be changed every 15 to 30 days.
Use a water test kit to control the parameters of the water before using the spa, or at
least once a week.
Use disinfection products for the spa. The treatment products should be used with
caution and it is imperative to refer to their instructions.
Damage resulting from improper use of treatment products is not covered by the
warranty
1. Water balance
The water balance (pH) must be maintain between 7 and 7.4.
2. Water Sanitation
To sanitise the spa water, we suggest using an active oxygen-based
treatment or bromine placed in a floating dispenser. (Dispenser sold
separately).
5.2. Cleaning and replacing the filter cartridge
A dirty filter cartridge may contaminate the spa water and cause damage to the heating function.
1. Unscrew the filter case by turning it anti-clockwise. Take out the filter cartridge from the
case.
2. Rinse off the filter cartridge with a garden hose. If the filter cartridge remains dirty
and discolored, the filter cartridge should be replaced.
3. Put back the cleaned filter cartridge into its case and screw it to the spa.
5.2a Disinfection
Water Sanitation:
To sanitise the spa water, we suggest using an active oxygen-based treatment or bromine
placed in a floating dispenser. (Dispenser sold separately)
Seek professional advice and guidance before doing this.
Attention:
Detergent residues and dissolved solids from bathing suits and chemicals may build
up on the spa walls. Use soap and water to clean the walls and rinse thoroughly with a
garden hose using a direct powerful water spray.
5. MAINTENANCE
EN
11
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wave Spa at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wave Spa in the language / languages: English as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info