PPL IMP 1234A
PROGRAM menu :
By pressing & keys the Program number starts to blink,
and use
& to see the
Then use
& to other days in the program
Select the program
Shows the daily program
If you select a built-in program “P1 to P9” and press this program will be followed in
Built-in programs description
P1 Morning, Evening & Week-end P6 Morning, Afternoon & Week-end
P2 Morning, Midi, Evening & Week-end P7 7h - 19h (Office)
P3 Day & Week-end P8 8h - 19h , Saturday (Shop)
P4 Evening & Week-end P9 Week-end (Secondary House)
P5 Morning, Evening (bathroom)
If you select a built-in program ”U1 to U4” and press you will enter in user program edition.
USER PROGRAM EDITION day
Hour at the cursor position
The key sets temperature at the current blinking program hour
The
key sets temperature at the current blinking program hour
Use & keys to slide the blinking cursor position in the day and modify or correct easily the
program. When the displayed day is correct press to jump to the following day.
When you press
on day 7 you return to the top menu
Now your user program will be followed if you put the MILUX RF in
operating mode.
Set CLOCK Menu :
Use this menu to adjust the clock .
Use & to
ajust the minutes.
Press key
Use &
Adjust the hours.
Press key
Use &
Adjust the day
Press key
COMFORT operating mode :
By pressing & keys the comfort
temperature starts to blink and can be adjusted.
The room temperature
reappears after a few
seconds
The MILUX RF regulation will now follow
indefinitely the comfort temperature.
AUTOMATIC operating mode:
MILUX RF will follow automatically the program
according to the actual time
By pressing & key you can override the
current set temperature until the next change in
the program.
The segment will lit up. Use & keys
to adjust the temporary required temperature.
At the next program change the will
disappear and the program continues without any
alteration.
RADIO CONFIGURATION WITH THE RECEIVER
1. To assign the MILUX RF thermostat with the receiver you must put the receiver in “RF init
mode, please refer to the receiver leaflet.
(In this mode the thermostat should be near the
receiver)
2. On the MILUX RF, select
operating mode.
Then press the key during 5 seconds,
you will enter in the Radio configuration mode (
).
The MILUX RF is now sending by radio signal its configuration address 4 times per second,
3. You can now perform a radio range verification.
Place the MILUX RF in the room where you need to regulate the temperature and leave it in
Radio configuration mode ( ).
Close the doors and come back to the Receiver.
Verify that the green LED blinks at each radio signal received :
- If it blinks regularly 4 times per second, the installation of the MILUX RF and Receiver is
correct.
- If it blinks irregularly, you are at the range limit. Install the MILUX RF closer to the Receiver.
- If it does not blink at all, you are out of range. Install the MILUX RF closer to the Receiver.
4. On the MILUX RF press on the key to exit the Radio configuration mode.
Now your MILUX RF controls the Receiver.
Wireless communication by radio signal to
the receiver connected to the
installation.
Range of approximately 30m in
residential environment.
7 day program
9 Built-in programs and 4 User programs
Program graphic display
Room temperature and time display
Comfort / Reduced / Anti-freeze
temperatures
Temporary temperature override
Automatic or Manual operation
Holiday function
Keypad lock function (child safety)
Battery operated, life >2 years
Battery weakness display
Battery replacement without loss of
the program memory (<1minute)
Reset function
ITCS function (optional). Intelligent
Temperature Control System.
1: Heater in operation
2: Temperature overridden
3: Holiday function activated
4: Operating mode menu
5: Batteries weak
6: Day of the week
7: Time
8: Current day graphic program display
and radio transmission activity
9: If lit-up 10 display the current room temperature
10: Room tem
p
erature or set tem
p
erature
REDUCED operating mode :
By pressing & keys the comfort
temperature starts to blink and can be
adjusted.
The room temperature
reappears after
a few seconds
The MILUX RF regulation will now follow
indefinitely the reduced temperature.
ANTI FREEZE operating mode:
Prevent your installation from freezing.
By pressing
& keys the anti freeze
temperature starts to blink and can be
adjusted.
The room temperature
reappears after a
few seconds
Now the MILUX RF will keep the
temperature above freezing.
OFF mode :
Use this mode if your Heating installation
needs to be turned OFF.
The MILUX RF will switch off the
installation and then switch itself OFF
(blank screen).
User programs are saved, time is kept
running and battery consumption becomes
very low.
Any key will wake up the MILUX RF.
The key display the actual room
temperature.
DANGER: has your thermostat is
stopped YOUR INSTALLATION CAN
FREEZE.
HOLIDAY Function :
With & keys, go to function. Then select with & keys the delay in hours
( H ) if below 24h then in days ( d ). Then select a mode or or .
The logo is active and the number of hours/days left is displayed until the MILUX RF
returns in mode and continues to follow the program.
KEYPAD LOCK Function :
Function to prevent any modification of the parameters.
In , , , and operating modes you can maintain the key pressed and
press simultaneously on the or key to lock ( ) or unlock ( ) the
keypad.
RESET Function :
Erase all user programs and sets the factory parameters by default.
Go to mode, maintain & keys pressed and press simultaneously on the key.
All segments will lit up during a few seconds showing that the MILUX RF has been erased and
restarted with factory defaults parameters.
Factory parameters are :
Temperatures 21°C 17°C 6°C, Program U1 all comfort.
CHARACTERISTICS
MODES DESCRIPTION
DISPLA
Y
SPECIAL FUNCTIONS
USER GUIDE
GB
Use & keys to change the mode in the Operating mode menu
For all operating modes the receiver switch should be placed on AUTO position.
C
hr
o
n
o
-Th
e
rm
ostat
MIL
U
X RF
TECHNICAL CHARACTERISTICS
Operating temperature 0°C - 50°C (o 32°F – 122°F)
Measured temperature precision 0.1°C (or 0.2°F)
Set temperature precision 0.5°C (or 0.5°F)
Set temperature range
in comfort & reduced : 5°C – 35°C (or 41 - 95°F)
in anti-freeze: 0,5°C – 10°C (or 33 – 50°F)
Regulation
characteristics
Cycle: 15 minutes
Anti-short cycle: 3 minutes OFF, 2 minutes ON
Electrical Protection Class II - IP30
Batteries
3x LR6 AA 1.5V alkaline batteries (> 2 years)
IMPORTANT: You have 1 minute to change the
batteries.Past this time, you may have to reprogram
your thermostat if all segments lit up at power up.
Radio Frequency 433.92 MHz, <10mW.
Certifications
CE. EN 300220-3, EN 301489-1
(Radio frequency certifications)
8
4
5
6
7
3
2
1
10
9
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts WFHTRF 010 -20433 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts WFHTRF 010 -20433 in the language / languages: English, Spanish as an attachment in your email.

The manual is 4,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Watts WFHTRF 010 -20433

Watts WFHTRF 010 -20433 User Manual - English - 4 pages

Watts WFHTRF 010 -20433 User Manual - English - 4 pages

Watts WFHTRF 010 -20433 User Manual - English - 2 pages

Watts WFHTRF 010 -20433 User Manual - German - 4 pages

Watts WFHTRF 010 -20433 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info