4. Inputs / Outputs
4.1 Power Supply
4.2 Heating/cooling Input
Purpose:
This input allows switching the regulation mode for the system: Heating or cooling.
Source of the signal:
• A mechanical switch
• A Heat Pump
A BT-WR02 RF paired on the BT-CT02 RF central unit as an ON/OFF device. This solution allows
getting a remote control of the H&C mode from the application.
Format of the signal:
The input could be free contact or live contact 230V.
Only one device in the system should be able to select the H&C mode. Other possible H&C switch signal source (See 3.3).
• Central unit (Set Manual H&C mode in the installer menu of the central).
• WFC-03 HCM RF 230 which embeds an H&C input.
Digital thermostat configured as a Master H&C thermostat in manual or automatic mode (only one thermostat
per installation).
If you have multiple WFC-03 HC RF in the system, the H&C mode should be controlled by only one controller:
• Without central, the system considers the controller set as the Main WFC-03 HC RF (Please refer to 5.1.2)
• With central:
. The controller which controls the H&C mode. DIP#4DIP#5= WFC-03 HC RF.
. The controller which does not control the H&C mode. DIP#4DIP#5= Central Unit BT-CT02 RF.
WFC-03 6Z HC RF 24 / WFC-03 10Z HC RF 24
Require to use transformer supplied by Watts
(4 cables): WAT TRF03 230/24
WFC-03 6Z HC RF 230 / WFC-03 10Z HC RF 230
Power
supply
Power
supply
Junction
earth
Junction
earth
230V/24V transfomer
Mode Free contact Live contact
Heating Opened No signal
Cooling Closed 230Vac
DIP4 DIP5 Changeover signal H&C request by
OFF OFF Central unit (BT-CT02 RF)
OFF ON Thermostat
ON OFF Heat&cool module (WFC-03 HCM RF)
ON ON Connecting box (WFC-03 HC RF)
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts WFC-03 HC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts WFC-03 HC in the language / languages: English as an attachment in your email.

The manual is 8.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Watts WFC-03 HC

Watts WFC-03 HC Quick start guide - English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info