2.3.3 System 3
System with 2 tanks, 2 pumps, 1 collectors array and 3
sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation).
The loading of the tanks is activated if the temperature
difference “dt between the collector (T1) and the tanks (T2,
T4) is sufficient.
You can choose different possibilities for the priority of the tank
loading. See parts “Priority Tank” for more information.
2.3.4 System 4
System with 1 tank, 1 pump, 1 valve, 2 collector arrays with
2 different cardinal direction (East / West) and 3 sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1, T4) and the tank1 (T2) is
sufficient. The valve direction of P2 is achieved by the warmer
of the two collector arrays.
2.3.5 System 5
System with 1 tank, 2 pumps, 2 collector arrays with 2
differents aspects (East / West) and 3 sensors. With this
system you can add an extra function with 1 sensor
(Thermostat, Cooling, Antistagnation).
The loading of the tank1 (T2) is activated if the temperature
difference “dt between the collectors and the tank1 is
sufficient.
The tank will be loaded by the warmer collector (T1 or T4).
P1 // P2
Use this function to authorize the run of the two pumps P1 and
P2 in the same time. (The tank will be loaded by both
collectors)
- To activate the function, press (+) or (-) to select the “P1 //
P2“ line and press (►) to active “yes” this function with (+) or (-
).
2.3.6 System 6
System with 1 collector array, 1 solar tank, 1 pump, 1 valve
and 4 sensors.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation or Booster).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1) and the tank1 (T2) is
sufficient.
Heating circuit return pre-heating:
If the "dt" between tank1 (T3) and heating return (T4) is
sufficient, the space heating return will be preheated through
tank1. This saves energy at the external heating source *.
2.3.7 System 7
System with 1 collector array, 1 solar tank, 2 pumps, 1
external heat exchanger.
With this system you can add an extra function with 1
sensor (Thermostat, Cooling, Antistagnation and diffcontrol
function).
The loading of the tank1 is activated if the temperature
difference “dt between collector (T1) and the tank1 (T2) is
sufficient.
Delay P2
You can choose a time delay for the start up of the pump
between the heat exchanger and the tank1. Default value is 1
minutes to give the heat exchanger time to heat up.
- With (+) or (-) select the line “delay P2” and press (►) to put
highlight the line.
- It is now possible to choose the delay for P2 start up with (+)
or (-). (Adjustable 0 to 30 minutes with factory value 1 minute)
2.3.8 System 8
System with 1 tank, 2 pumps, 1 collector array, 3 sensors
and 1 plate heat exchanger. With this system you can add
an extra function with 1 sensor (Thermostat, Cooling,
Antistagnation or booster).
P1 P2
System
3
T1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2 T4
P2
P1
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
System
4
T1 T4
T2
P1 P2
System
5
T1 T4
T2
T1 _ _ _°C
T2 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
 System --- -
System 5
P1||P2 No
P2
*
P1
System
6
T1
T1 _ _ _°C
T2 _ _ _°C
T3 _ _ _°C
T4 _ _ _°C
P1 _ _ _ %
T2
T4
T3
P1
P2
System
7
T1
T1 _ _ _°C
T2 _ _ _°C
P1 _ _ _ %
P2 _ _ _ %
T2
 System --- -
System 7
Delay P2 2min
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts Solar Controller LCD PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts Solar Controller LCD PLUS in the language / languages: English, German as an attachment in your email.

The manual is 1.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info