805504
2
Zoom out
Zoom in
Previous page
1/2
Next page
8. Special functions
8.1. HOLIDAY function :
Go to HOLIDAY mode by using navigation keys (◄) and (►). The
pictogram and the text nomust flash:
You can adjust the duration. Press (+) or (-) keys to adjust hour number (H) if it is
less than 24 hours, then the day number (d).
With navigation keys (◄) and (►), select the comfort or reduced or
antifreeze mode. The pictogram and the remaining number of hours /
days will be displayed until the period’s end:
Once completed, the thermostat will switch on automatic mode .
To stop holiday mode before the period’s end, go to HOLIDAY menu with
navigation keys (◄) and (►). pictogram and the remaining time flash. Use (-)
key to display noand validate with (OK) key.
8.2. Keypad lock
This is a prevention function against any parameter change. It is valid in comfort
, automatic , reduced and antifreeze mode.
To lock the keypad, maintain (OK) key pressed then press on (-) or (+) keys.
is displayed.
To unlock the keypad, maintain (OK) key pressed then press on (-) or (+) keys.
is displayed.
8.3. Cooling function :
You can use your MILUX RF to control a cooling system (air-conditioner…). To
change thermostat operating mode, move the cursor on the comfort menu
with navigation keys (◄) and (►). Then, maintain (OK) key pressed and press
simultaneously on (◄) key. One of the below screens must appear:
Use (+) or (-) keys to modify the operating mode. Press (►) key to come back to
the main screen and to validate your selection.
In cold mode “COLD”, the antifreeze mode is removed.
8.4. RESET function :
This function is used to erase all programs and to restore the default
manufacturing parameters.
Go to TIME SETTING menu , maintain (OK) key pressed during 10 seconds.
All display’s segments will light up. It will demonstrate that the thermostat is in
reset phase. Once completed, the thermostat restarts in the delivery configuration
with the following default settings:
U1 to U4 programs reset all in comfort.
In heating mode :
Setting temperatures: 21°C, 17°C, 6°C.
In cooling mode:
Setting temperatures: 22°C, 24°C
WARNING: Remember to adjust time value after the reset (see chapter
7.1)
9. Battery replacement
Once the low battery pictogram is displayed, you have to replace the batteries.
Put on the clip on the left side and pull the front face to remove it :
Replace the both batteries:
Close the thermostat by placing the front face in front of the rear face
and push on it to lock:
WARNING: Remember to adjust the value of the time after the reset
(see chapter 7.1)
10. ITCS function (optional)
Your thermostat has an Intelligent Temperature Control System (ITCS). It will
activate your installation in advance to ensure the desired temperature at the hour
programmed following your weekly program.
To operate, this Intelligent Temperature Control System realizes automatically
several time measurements. When you switch on your thermostat for the first time,
a time measurement taken to reach the setting temperature is realized. This time
will be adjusted by new measurements at each program change to offset the
outside temperature evolution. Then, you can program your thermostat without
temperature adjustment because it will be done automatically for you.
11. Technical characteristics
Environment. (Temperatures)
Operating temperature:
Transport and storage :
0°C - 40°C
-10°C to +50°C
Measurement precision
0.1°C
Set temperature range :
Comfort and Reduced
Antifreeze
5°C - 35°C by 0,5°C step
0,5 - 10°C by 0,5°C step
Regulation characteristics
Cycle (PWM): 15 minutes for 2°C with Anti-
short cycle of 3 minutes in OFF and 2
minutes in ON.
Electrical Protection
Class II - IP30
Batteries &
Operating life
2 LR3 AAA 1.5V Alkaline batteries
~ 2 years
Sensible elements:
Internal
NTC 10k ohms at 25°C
Radio frequency
868.3 MHz, <10mW
CE Directives
Your product has been
designed in conformity with the
European Directives.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
Product conformed to :
Classification :
Contribution :
UE 811/2013 and 2010/30/UE
IV
(2%)
12. Problems and solutions
My thermostat doesn’t switch on
Battery problem
- Check that the batteries protection is well removed.
- Check the direction of the batteries.
- Check the batteries charge
- Check the switch position
My thermostat displays an error message
Sensor problem
The message Err is displayed and the pictogram
flashes (ambient sensor)
Low batteries
The pictogram flashes
- Replace the batteries
My thermostat seems to operate correctly but the heating doesn’t function
correctly
Output
- Check the receiver connections.
- Check the power supply of the heating element.
Radio
communication
- Receiver must be placed at a minimal distance of 50cm
from any electrical device or wireless communication
system (GSM, Wi-Fi..)
- The receiver should not be attached to a metal part or
too close to hydraulic line (copper, …)
In case of persistent problems, contact your installer or seller.
13. Recycling
Electrical and electronic out of order appliances must be collected
separately by using specific systems in your country.
Batteries should not be recycled with household waste but collected
in suitable collection systems
14. Annexes
Comfort =
Reduced =
= daily version
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts Milux 2 RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts Milux 2 RF in the language / languages: English as an attachment in your email.

The manual is 0.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info