805571
7
Zoom out
Zoom in
Previous page
1/17
Next page
7
Second step: control the circuits
For each circuit, you can link an element to drive the
pump/boiler of the circuit. This can be done for example by BT-
WR02 RF.
From the main screen, press then press . On the list
box, choose “Radio pairing”, then “Circuit”. Select the number of
the circuit, put the element to link (BT WR02 RF) in link mode,
then start process by pressing .
Do the same for the other circuit, if you have more.
Heat and Cool installations
If your installation can make cooling, then you can switch either
from Heat to Cool manually or automatically:
- If you have a BT HCM02 RF in your installation set as
“Master” (refer to Manual instruction of the device) then all
is automatic you don’t have to do anything
- For all other cases, you have to do the switch manually:
from main screen press then and go in “H&C”.
There you will have the choice netween “Heating Only”
“Cooling Only” or “Manual Reversible”. With this last
option, you create a shortcut in the main menu (icon 4)
where you can easily change Heat/Cool mode.
Notes:
- In Cooling Mode, Reduced mode and Antifreeze mode are
inactive: icon is displayed instead of or .
- In the thermostat, user can configure the parameter “Cold”
that allows the zone to do Cooling or not. If it is set to “No”,
then if the mode of the zone is Cooling then the zone
won’t make Cooling.
INSTALLATION TYPES
(HEATING/COOLING)
Type 1 :
In this configuration:
Pair first the thermostat (master) with the Central before
pairing the other devices.
The actuators regulate on thermostat temperature.
Type 2 :
In this configuration:
Pair first the thermostat (master) with the Central before
pairing the other devices.
The other devices regulate on thermostat temperature.
Warning! In this installation type, the BT (MASTER) must be in
regulation Air mode (not floor or Air + Floor)
Type 3 :
In this configuration :
BT-WR, BT-PR, BT-FR can be configured as a plug or
lighting devices.
Type 4 :
In this configuration:
Each UFH 1 is paired with the Central and the thermostats
are paired with UFH.
During the pairing, the Central create automatically rooms
according to the number of thermostats (rooms) of UFHs.
Default names are given to the rooms. You can modify them
in the menu “House creation” (you can identify these rooms
with different setting temperatures)
REMOTE CONTROL
You need to connect the central unit to WiFi: See WiFi setting
above.
Make sure that the central is connected to the WiFi network with
an IP address (See WiFi status above) otherwise you need to
connect the central unit to WiFi.
Connect to the web pages to drive your central unit:
http://smarthome.wattselectronics.com/
Or download WATTS® Vision™ application from App store or
Google Play on your Smart Phone.
Create an account.
Validate your email.
Request a pairing code to link your central unit to your account.
The pairing code (valid 24h) is sent to your mail box.
In the WiFi status menu of the central unit, enter the pairing
code.
Your central unit should appear after a few minutes in the
application or the web page. It may take up to a few hours to
display all rooms and devices in the application. You can then
drive your central unit from everywhere.
Watts is not responsible for the correct operation of the
connected devices, and potential damage caused by
malfunction or improper use of the connected devices and
appliances.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts BT-CT02 Central Unit at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts BT-CT02 Central Unit in the language / languages: English as an attachment in your email.

The manual is 1.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Watts BT-CT02 Central Unit

Watts BT-CT02 Central Unit Usermanual and installation guide - English, German, Dutch - 240 pages

Watts BT-CT02 Central Unit Usermanual and installation guide - Dutch - 10 pages

Watts BT-CT02 Central Unit Usermanual and installation guide - Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish - 240 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info