533643
21
Zoom out
Zoom in
Previous page
1/59
Next page
21
GB
Installation Instructions for the Véro
General instructions 21
Preparation 21
Installation 22
Repairs 24
Technical details Véro / Véro 33 / Vérox 24
General instructions
The Véro is tested in accordance with the international
EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to flue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a flue tube
to which several stoves are connected. The flue tube has
a diameter of 150 millimetres.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee
if the Véro is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2
dwellings.
Spaces where highly flammable or explosive materials
are used.
Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Before placing the stove you must observe the following
points:
If the stove is connected to an existing chimney, you
must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
The flue tube of the stove must be connected with the
chimney without diversions.
The underpressure in the chimney must be at least 12
Pa or 0.12 mbar.
The chimney flue must always end up in outlet area 1
(see the drawing and the table below)
Roof slope x larger than 23° Roof slope x smaller than 23°
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Vero at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Vero in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 5,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wanders Vero

Wanders Vero Additional guide - English, German, Dutch, French - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info