The appliance may only be installed and connected by a certied installer in accordance with the standard
gas installation instructions and the installation requirements mentioned below. Furthermore, the national
and local rules and regulations on placing and using closed gas appliances shall be applicable. Only a certied
installer has the authority to change the setting values (in accordance with the requirements) and to carry out
any other adjustments.
Before installing the appliance, the installer must check whether the information on the type tag of
the replace corresponds with the gas type and gas pressure to which the appliance is connected. If it
does not match, you are not allowed to connect the gas hearth.
Placing
The gas hearth was designed to be built into a newly-built replace made of incombustible material. If there
are any ammable materials behind or along the gas stove, you will have to place reproof sheets.
The gas replace can be placed in a crack-free and/or mechanically ventilated home without diculty. There
is no need for extra ventilation for combustion or for a smoke and re vent. Waste gases are discharged by
natural draught via the inner pipe into the open. The oxygen needed for burning the re is supplied from the
space between the pipes. This is the reason that no insulation must be placed between the inner and outer
pipe.
Insulation
Due to the high temperatures of the exterior walls (up to approximately 150 °C or 300 °F) it is prohibited to
have or to place any combustible materials close to the channel system. The entire concentric pipe system
should be encased with reproof material from the place where it is out of sight up to the outlet in the exterior
wall. Ventilate the encased concentric pipe system by placing a grate near the oor and the ceiling on every
oor. Use universal wall clips with a diameter of 150 mm for anchoring the concentric pipe system.
If an existing chimney is used, rst make sure whether the chimney is suciently insulated and is wide
enough to accommodate the concentric pipe system. If the chimney was previously used as a wood-burning
or coal-red stove, it must rst be professionally cleaned. You must use special WANDERS connecting sets for
connecting a gas hearth to an existing chimney.
Gas connection
t Use a feed pipe with an approved G3/8” stop cock with coupling. The gas connection is located on the
right side of the appliance.
t De-aerate the supply pipe before tting and fastening the appliance.
t Avoid tension on the operating valve and pipes to avoid gas leakage.
t Check if the connection is gastight.
Electro-technical details
t The connection diagram for the ventilator and the remote control is given on page 60.
t The installation is based on 230Vac 50 Hz and the protection level is IP20.
t The installation must be done in accordance with the current national and local requirements.
t The stove must always be connected to an earthed socket. It is not allowed to operate the stove without
an earthed connection.
t If work is done to the stove or the electric parts, you must always disconnect the plug from the power
point rst.
t The power point must always be within reach.
t If the connecting ex or cable is damaged, you must replace it by an original cable provided by the manu-
facturer.
!
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Square 60G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Square 60G in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 5,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wanders Square 60G

Wanders Square 60G Additional guide - English, German, Dutch, French - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info