694501
22
Zoom out
Zoom in
Previous page
1/56
Next page
22
GB
Ventilation in the hearth
We advise adding ventilation to the hearth where possible. These ventilation holes, both above and below the
stove, must be at least 400 cm2 in size. Do not t the upper ventilation grills too close to the ceiling.
The chimney ue
Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must rst have the chimney professionally cleaned and
checked by a qualied chimney sweep company. Any cut-o valves or stop valves must be removed.
The ue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney ue must always end up in
outlet area 1 (see the drawing and the table
below)
At the time of placing the stove, the chimney
ue must be clean, leak-proof and without
obstructions, and must have a diameter of
150 mm.
Any bends in the ue tube must not exceed
45 degrees.
Ensure that the chimney tube can discharge
the ue gases adequately, properly and
safely.
Fire Safety
For reasons of re safety is it important to observe the instructions below before installing the stove.
1. If the oor around the stove is made of combustible material, you must use a oor slab. The oor slab must
measure at least: - 50 cm from the stove on the front side of the door - 30 cm from the stove on the sides of
the door.
2. Keep at least a distance of 80 cm between the stove and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects. Keep the same distance from the ue tube.
3. Wooden construction parts within the radiation range of the stove (80 cm from the exterior of the stove) must
be covered with reproof material.
4. If the ue tube goes through a ceiling and/or roof that consist of ammable materials, the ceiling and the roof
must be covered with reproof materials all around (about 80 cm). Pay also attention to joisted oor layers
and any electric wiring.
5. Keep a distance of at least 50 cm (in all directions) between the stove and supporting steel construction parts.
6. Shield o all combustible materials within a radius of 80 cm from the stove openings with non-combustible
materials.
7. Never cover the chimney breast with combustible material (e.g. paper covering).
8. The wall behind the stove must be made of reproof materials or be insulated. The insulation material must be
able to withstand temperatures of 700 degrees Celsius and have a density of at least 80 kg/m3.
Installation
The S60/S75 is approved in accordance with the international standard EN 13229 and has an extra supplementary
standard for optimal environmentally friendly combustion in relation to ue gases (art. 15a B-Vg. Des BmfWA). The
stove can be connected to a ue to which several other stoves are connected. The pipe for ue gas extraction has
a diameter of 150 millimetres (connection 146 mm external).
Combustion air supply
The stove must have an adequate combustion air supply. If necessary, create an extra air supply as close as possible
to the stove, as this prevents draughts. The air supply in the room should be at least 150 cm2 in size. An extra air
supply is absolutely necessary if:
The dwelling is tted with a heat-recovery system.
The dwelling has a central vacuum system.
There is an extractor hood in the same room.
1
3 3
A X
X > 23˚
3
X
X < 23˚
1
500 mm
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders S60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders S60 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info