694510
27
Zoom out
Zoom in
Previous page
1/72
Next page
27
GB
Placing possibilities for the pipe system
The total length of the pipe system must never be more than 10 metres excluding the passage through the wall and the
outow. The maximum horizontal length is 3 metres. A 90° square angle counts as a length of 2 metres. A 45° turn counts as
a length of 1 metre.
For the combined ue tube and combustion air supply you must apply one of the following set-up possibilities of the WANDERS
concentric pipe systems: with wall duct, with roof duct, or with roof duct with bend.
Because of the high outer temperatures of the ue system (around ± 150°C) it’s not allowed to use flammable materials
near the flue system. Therefore it is advised to surround the flue system, on locations where it is not in direct view, with non-
flammable materials. Make sure this construction is sufficiently ventilated (per floor) by installing ventilation grids near the floor
and the ceiling.
It’s not allowed to insulate the concentric ue system.
Use approved wall brackets Ø150 mm to attach the sleeving of the concentric channel system [Ø 100 mm - Ø 150 mm].
Select one of the connection possibilities. Then build up the rst metre of concentric pipe from the counterpart in the appliance.
If you can see the blue rubber ring in the pipe from above, you will know that the assembly is correct. Keep a distance of at
least 5 centimetres between the outer wall of the concentric pipe and the ceiling. Always start with 1 meter vertical.
Pay special attention to proper installing when, due to circumstances, a part of the double-walled pipe system must be built in.
Wall outlet (type C11)
Always allow one metre vertical before passing through the outer wall.
The maximum length for a horizontal segment is 3 metres. When using LPG the maximum horizontal length is 2 metres.
Determine the location of the appliance and the exterior wall duct.
Make an opening of Ø 160 mm for the wall duct.
Connect the wall duct vertically with a curve to the mouth of the appliance, push them rmly together and place the clip
binding. The blue rubber ring ensures sucient sealing of the outlet of the ue gas system.
If the appliance is placed more than 1 meter from the outside wall, place the rst meter on top the appliance, then the elbow
followed by the wall outlet. Finally make sure the construction is gastight.
Mount the wall brackets with the appropriate diameter, following the instructions on page 26.
Roof outlet (type C31)
The roof outlet may pass through any point of the roof, with a bend to the ridge, if so desired. The roof outlet is supplied with
a universally adjustable plate for a sloped roof, or with an adhesive plate for a at roof.
Determine the location of the hearth and the roof outlet.
Make an opening of Ø 160 mm.
Connect the pipes vertically to the outlet of the hearth, press it in place and secure it with the clip.
Determine the length of the pipes you need, and ensure that the adhesive strip or the universal tile is properly linked up with
the roof.
Saw the outer pipe o to measure and link the roof outlet to the concentric pipes.
Mount the wall brackets with the appropriate diameter, following the instructions on page 26.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Larix at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Larix in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info