533294
39
Zoom out
Zoom in
Previous page
1/65
Next page
38
Positionnements de la canalisation
possibles
-BMPOHVFVSUPUBMFEFMBDBOBMJTBUJPOOFQPVSSBKBNBJT
être supérieure à 10 m, la traversée murale et le débouc
OZÏUBOUQBTDPNQSJT-BMPOHVFVSDBMDVMÏFEVODPVEF
de 90º est de 2 m et celle d’un coude de 45º est de 1 m.
(Il ne doit pas y avoir plus de 2 coudes à 90°)
Pour le double tuyau d’évacuation des gaz de fumée et
d’amenée d’air de combustion il faut appliquer un des
placements possibles pour la canalisation concentrique
de WANDERS : une traversée murale, une traversée de
toit ou une traversée de toit avec déplacement.
Traversée murale
t 1PVSMBUSBWFSTÏFNVSBMFDPNNFODF[QBSNPOUFSVO
tuyau vertical de 1 m.
t %ÏUFSNJOF[MFNQMBDFNFOUEFMBQQBSFJMFUMBQMBDF
de la traversée murale.
t 1FSDF[VOUSPVEFNNËMFOESPJUEFMBUSBWFSTÏF
murale.
t 3BDDPSEF[MBUSBWFSTÏFNVSBMFËMBCPVDIFEFMBQQBSFJM
au moyen d’un coude. Pressez et montez les bandes
EFTFSSBHF-BCBHVFFODBPVUDIPVDCMFVBTTVSFVOF
étanchéité suffisante du système d’évacuation des gaz
brûlés.
t 4JMBQQBSFJMTFUSPVWFËQMVTEFNEVNVSNPO-
tez d’abord le tuyau vertical sur l’appareil, ensuite le
coude et la traversée murale et rendez celle-ci étanche
au gaz.
Gaztype A (min.-max.) B (min. - max.) retenue
Nat. gaz 1,0 - 3,0 m 0 - 0,5 m NON
Nat. gaz 1,2 - 3,0 m 1,0 - 3,0 m NON
all lengths are exclusive the wall outlet
Traversée de toit
Une traversée de toit peut déboucher à n’importe quel
point du toit, éventuellement avec un déplacement vers
MF GBÔUF -B USBWFSTÏF EF UPJU FTU MJWSÏF BWFD VOF UVJMF
universelle réglable pour un comble en pente ou une
plaque collante pour un toit plat.
t %ÏUFSNJOF[MFNQMBDFNFOUEFMBQQBSFJMFUMBQMBDF
de la traversée de toit.
t 1FSDF[VOUSPVEFNNËMFOESPJUEFMBUSBWFSTÏF
de toit.
t 3BDDPSEF[MFTUVZBVYDPODFOUSJRVFTWFSUJDBMFNFOUË
la bouche de l’appareil. Pressez et montez la bande
de serrage.
t %ÏUFSNJOF[ MB MPOHVFVS EFT UVZBVY OÏDFTTBJSFT FU
faites en sorte que la plaque de solin ou la tuile uni-
verselle s’ajuste bien au toit.
t $PVQF[ MF UVZBV FYUÏSJFVS Ë MB MPOHVFVS TPVIBJUÏF
et raccordez la traversée de toit aux tuyaux concen-
triques.
Gaztype A (min. - max.) retenue
Nat. gaz 5,0 - 10,0 m Ø 50 mm
Nat. gaz 1,0 - 5,0 m Ø 65 mm
all lengths are exclusive the roof outlet
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Kanda 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Kanda 100 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 8,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wanders Kanda 100

Wanders Kanda 100 Additional guide - English, German, Dutch, French - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info