533431
25
Zoom out
Zoom in
Previous page
1/63
Next page
25
GB
Height of chimney on the roof at a horizontal distance A measured from the ridge
Horizontal distance A from the ridge, in metresRoof with
slope X
On the
ridge 0.5 m 0.75 m 1 m 1.25 m 1.5 m 2 m 3 m 4 m
25
o
0.5 0.75 0.85 1.0 1.1 1.2 1.6 2.5 3.3
30
o
0.5 0.85 1.2 1.6 2.0 2.4 3.2 4.9 6.5
35
o
0.5 1.0 1.8 2.4 3.0 3.6 4.8 7.3 10
40
o
0.5 1.2 2.4 3.2 4.0 4.8 6.4 10 13
45
o
0.5 1.5 3.0 4.0 5.0 6.0 8.0 12 16
Roof slope x larger than 23° Roof slope x smaller than 23°
Keep the same distance from the flue tube.
3. Wooden construction parts within the radiation range
of the stove (80 cm from the exterior of the stove) must
be covered with fireproof material.
4. Keep a distance of at least 50 cm (in all directions)
between the stove and supporting steel construction
parts.
5. If the flue tube goes through a ceiling and/or roof
consisting of flammable materials, the ceiling and
the roof must be covered with fireproof materials all
around (about 80 cm). Also pay attention to joisted
floor layers and any electric wiring.
6. Never cover the chimney breast or the wall with
combustible material (e.g. paper covering).
7. Walls and other materials that are located within 80
cm from the fireplace must consist of, or be insulated
with, fire-proof materials. The insulation material
to be used must resist a temperature of 700 °C and
have a density of 80 kg/m3. (Please see page 29 for
insulation materials).
8. Avoid heat transmission when placing the stove and
the flue gas tube. Heat transmission of a burning stove
may penetrate the wall and even cause fire damage
on the other side of the wall. Prevention is better than
cure.
Installation
The Economic is tested in accordance with the
international EN 13240 standardization, and has an extra
additional standardization for optimally environment-
friendly heating devices related to flue gases (Section
15a B-Vg. Des BmfWA). The stove can be connected to
a flue tube to which several stoves are connected.
Supply of combustion air
The stove must have a sufficient fresh supply of
combustion air. To avoid draft, make if necessary an
extra air supply opening as close to the stove as possible.
An extra air supply opening is definitely required if:
the room has a heat recovery system.
the room has a central exhaust system.
the same space has a cooker hood.
The air supply opening must be sealable if it goes through
a fire-resistant wall. If there are several heating devices
in the same room there must be enough air openings to
guarantee proper combustion.
Electricity
You must have an electricity supply (230V) for the
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Economic 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Economic 60 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wanders Economic 60

Wanders Economic 60 Additional guide - English, German, Dutch, French - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info