installation, servicing and user instructions manual | GB + IE
27
4. Servicing
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start
servicing the appliance. No liability can be accepted by Wanders for injury caused by burning or scolding by a hot
appliance.
A suggested procedure for servicing is listed below.
A. Lay out dust sheet on ooring, mask o any special replace materials.
B. Remove Side Window Trims
C. Remove Bottom Window Trim
D. Remove Window Assembly
E. Carefully remove the Ceramic components (including Embers) or Gravels
F. Use a Vacuum cleaner to clean the top of the burners and grate
G. Remove Grate
H. Remove all 3 Burner Top assemblies, there are 3 M6 ange bolts holding each in
I. Using a vacuum cleaner, fully clean both Burner Top.
J. With the Burner Tops now removed, the Pilot and the heads of the injectors are clearly visible. Use the
vacuum cleaner and a soft brush to clean the pilot assembly and both Injectors. Never modify or bend the
Thermocouple
K. Replace the burner top assemblies and x in with the xings
L. Turn on the gas supply and check for leaks, check the burners and Pilot for good condition and operation
M. Replace Grate
N. Replace the Firebed arrangements
O. Replace Window Assembly and Trims
P. Check the ue system and terminal, making sure that the terminal vent is fully clear
Q. Light the appliance and test setting pressures
R. Check the safe operation of the appliance.
4.1 Cleaning the Ceramics
• Remove the ceramics as detailed in A - E above.
• Gently clean the ceramics in the open air, using a soft brush and a vacuum cleaner. Where necessary replace
damaged components only with genuine Wanders specied parts. Seal any scrap ceramics in plastic bags and
dispose at proper refuse sites. When using a vacuum cleaner, it is recommended that one with a HEPA ltering
system is used.
• Re-t the Firebed arrangement, re-seal the appliance and check the safe operation of the appliance.
4.2 Servicing the Burners
• Remove the Burner Top Assemblies as detailed in A - H above.
• The pilot is now clearly visible, the pilot, including the Thermocouple, can be replaced/serviced by removing
raising the pilot assembly from its mounting. This is done by removing the two screws on the surface of the
pilot. The ttings on the under-side of the pilot can be un-done using a 10mm spanner where appropriate.
• To access the Main Burner Injectors, the Burner base units must be removed. This is done by removing the six
bolts (M6, 10mm spanner) holding the burner in. With these six bolts removed, the Burner base can be raised
up through the Firebox, and the Injectors can be easily accessed.
• When replacing any parts use only original Wanders specied parts.