813184
27
Zoom out
Zoom in
Previous page
1/64
Next page
27
for the chimney sweep and be properly insulated against condensation. The line
should not be longer than 4 m and not have more than 3 bends. If the line leads out-
doors, it should be provided with a suitable windbreak and fly screen.
General information on the subject of room air dependent or room air inde-
pendent operation:
The stove is supplied as a standard room air-dependent fireplace stove. This means
that the stove draws all of the combustion air from the installation room via the central
air intake on the back. A sufficient supply of combustion air (at full load approx. 25m³ /
h) is absolutely necessary.
In combination with ventilation and air conditioning systems (e.g. controlled ventilation
systems, fume hoods, etc.), Section 4 of the Firing Ordinance (FeuVO) is decisive in
Germany. The flue gas routing must be monitored by special safety devices (e.g. via
an approved differential pressure monitor) or, if a ventilation system is used, this must
ensure that no negative pressures greater than 4 Pa occur in the installation room
compared to the outside and that the necessary combustion air (approx. 25 m3 / h) for
the fireplace.
Please always observe - in consultation with your authorized district chimney sweep -
the applicable local regulations and rules. We cannot accept any liability for changes
made after this manual has been printed. We reserve the right to change without no-
tice.
The above-mentioned safety devices are not a substitute for professional planning
and design of an adequate combustion air supply.
As part of the acceptance, the district chimney sweep must check the adequate com-
bustion air supply / overall installation.
2.6 Choice of flue gas and air connection placement
The following steps must be observed when converting the flue gas connection:
1. Drill out the existing
3mm holes with a 6mm
drill (6x)
2. Drill out the three blind
rivets of the inner sheet
metal with a 6mm drill
and remove them. Be
careful not to let the
tray fall into the oven.
1
2
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler Pylon 1G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler Pylon 1G in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info