glowing embers, put additional fuel on the fire. Thereafter, adjust the primary air regu-
lator according to the Table 1 („Adjustment of the burning air”). The first kindling
should be performed “finely” with little fuel only, so that the parts of the fireplace be
adapted to heat. During the first kindling, the generation of smell is normal.
1.3 Putting out of operation
Let the glowing ember burn to ashes and the fire-place get cold.
Empty the furnace chamber and the ash bin.
Close the doors and push the primary air regulator totally to the right.
1.4 Heating instructions
The fireplace should be operated only with closed furnace chamber door. Fireplaces
belonging to type 1 have self-locking furnace chamber doors. These doors may be
opened only for kindling, loading or when cleaning the furnace chamber (otherwise
draught problems may occur with other equipment connected to the same chimney).
Warning!
When opening the furnace chamber door, any incorrect handling or insufficient
draught may induce smoke. Always ensure that the furnace chamber door may
be opened only slowly, first just to a small extent, and then fully after a few sec-
onds. In addition, if you intend to put additional fuel into the fire, before the
opening of the door only there may be only ember bed in the burning space, i.e.
no flames may be visible.
Led into the burning space in correspondence with the existing conditions, the secon-
dary air provides for the follow-up burning of the combustible components of in the
burning space. This in fact means smoke and soot-poor burning, which contributes to
the protection of the environment. If you wish to commission the fireplace in a transi-
tional period, please, please first examine the chimney draught, as it can be especially
weak at high external temperatures. Towards this end, hold a burning match in the
slightly opened feeding door. If the flame is not drawn significantly by the draught,
then a so-called starting fire is to be set first. Towards this end, burn wood chips/wool
in the fireplace or the cleaning hole of the chimney. The fire grate is to be cleaned
before every kindling to ensure the proper inflow of air for burning. The ashtray is to
be emptied regularly. Should the equipment be extremely hot, use the gloves pro-
vided. Please, be careful not to dispose glowing materials into the waste bin.
Ensure that the ashtray should be fully pushed into the equipment.
Warning! In order to keep the air clean and safeguard the fireplace, do not ex-
ceed the specified maximum fuel quantity, otherwise overheating may occur,
which potentially damage the equipment. Such damage is not covered with any
guarantee. Only a single layer of fuel is allowable to be prepared in the fireplace.
Try to reach lower heating performance only by decreasing the quantity of fuel,
and not by cutting the primary air supply.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler Pylon 1G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler Pylon 1G in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info