531873
30
Zoom out
Zoom in
Previous page
1/82
Next page
30
GB
2. Placing
2.1 Prescriptions
When placing the fire-place and jointing the smoke tube side the fire protection
requirements of the relevant construction provisions must be taken into consid-
eration.
For the problem-free functioning of the equipment the chimney which the fire-
place uses must be in perfect condition.
2.2 Place of installation
Since the air which the fire-place takes comes from the room where it is located
fresh supply of air must be sufficient. Make sure that 4 m
3
volume of air falls to
each KW of nominal performance.
For this specific fire-place this means that the room must be at least 26 m
3
. If the
room is less than 26 m
3
then sufficient air supply can be secured by opening more
rooms together (size of the linking slots must be at least 150 cm
2
).
2.3 Distances
All combustible equipment, furniture or e.g. decoration materials which are in the
close environment of the fire-place shall be protected from the heat.
Furnishings in the radiation area
Keep a minimal distance of 80 cm (A) between the front cover of the fire-place
and the combustible equipment, furniture or e.g. decoration materials.
The security distance can be lowered to 40 cm if a heat shield is put in front of the
object to be protected (B) (see our example on drawing no. 6).
Furnishings outside the radiation area
The walls beside and behind the fire-place shall not be made of combustible ma-
terials and they cannot be covered by such materials, unless the distance on the
sides is more than 30 cm and behind is more than 20 cm.
Similarly to the wooden and plastic furniture on the sides a distance of 30 cm
shall be kept (see drawing no. 7).
picture 6
picture 7
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler KF 198 55 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler KF 198 55 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info