5.2 Heating output data
The following table shows burning time, water output and heat emission (to the room
where it is installed) of your stove under normal conditions according to EN 12815 con-
cerning the charge quantities and control setting for the fuel materials coal and wood.
Output table according to EN 12815:2005
* brown coal Hu = 5.41 kWh/kg
wood Hu = 4.05 kWh/kg (residual moisture max. 20 %)
**with closed top lid
If coal is used which is not the common domestic grain then the amount of draw needed for
nominal heat load (NHL) increases and it is necessary to riddle more frequently.
The stove combustion chamber holds around 30% more fuel than shown in the capacity
table. Burning time increases accordingly.
Model 158 Fuel * Tempera-
ture con-
trol setting
Secondary
air Quantity Total
output
kW
Water
output
kW
Heat
emission
to room
kW **
Nominal
thermal
capacity at
12 Pa
brown
coal
3 OPEN
10,6 kg / 2h
21 14 7
Wood
6,6 kg / 1h
22
14
8
Model 158F
Fuel * Tempera-
ture con-
trol setting
Secondary
air Quantity Total
output
kW
Water
output
kW
Heat
emission
to room
kW **
Nominal
thermal
capacity at
12 Pa
brown
coal
3 -
10,6 kg / 2h
22 14 8,2
Wood
6,6 kg / 1h
22
14
3,3
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler K158 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler K158 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info