PerfectPower Fastening and connecting the inverter
35
Sample circuit diagram legend:
Install a residual current circuit breaker in the socket distribution circuit.
Setting grounding bridge (fig. 4, page 4)
!
WARNING! Danger of electrocution!
The grounding bridge may only be connected by a trained profes-
sional who is familiar with the relevant VDE (German Engineering
Society) regulations.
I
NOTE
The grounding bridge plug is always plugged into socket “FG”
(insulated AC current) when delivered.
Unscrew the top four fastening screws (2) on the front of the device with
a hex key.
Take off the cover (1).
A
NOTICE!
The grounding bridge is changed with sockets “FG” and “N + FG”.
Do not alter the other sockets, otherwise the device may be dam-
aged.
Remove the plug (3) from socket “FG” (4).
Insert the plug (3) into socket “N + FG” (5).
Replace the device cover (1) and fix using the screws (2).
No. in fig. 6,
page 5
Explanation
1 230 V
AC
power source
2 Additional devices, e.g. battery charger, refrigerator
3 DC power source (battery)
4Inverter
5 Grounding bridge set
(At delivery: not set, shown by dotted line)
6 Circuit breaker (residual current circuit breaker)
7 Socket distribution circuit for consumers
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Waeco PerfectPower PP1004 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Waeco PerfectPower PP1004 in the language / languages: All languages as an attachment in your email.

The manual is 1,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info