Troubleshooting COOLMATIC MDC Series
34
11 Troubleshooting
Error code LED
The error code LED indicates various faults with a different number of
flashes. One flash lasts a 1/4 of a second. The error codes are repeated
every 4 seconds.
Compressor does not run
Number of
flashes
Error type Possible cause
1 Battery protection shut
down
The battery voltage is outside of the set range
2 Fan overvoltage shut
down
The fan is consuming more than 0.5 A on average
or 1 A peak values from the electronic unit
3 Motor start error The rotor is stuck or the differential pressure in the
cooling system is too high (> 5 bar)
4 RPM too low If the cooling system is overloaded, the minimum
speed of the motor of 1900 RPM cannot be
maintained
5 Thermal shut down of
the electronic unit
If the cooling system is overloaded or the ambient
temperature is too high, the electronic unit
becomes too hot
Fault Possible cause Remedy
U
T
= 0 V The connection between the battery
and the electronics is interrupted
Establish a connection
Main switch defective (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the fuse
U
T
U
ON
Battery voltage is too low Charge the battery
Start attempt with
U
T
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low Replace the battery
Cable cross section too low Replace the cable
(fig. 7, page 5)
Start attempt with
U
T
U
ON
Ambient temperature too high
Insufficient ventilation Move the cooling device
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
U
T
Voltage between the positive and negative electronic terminals
U
ON
Switch-on voltage of the electronics
MDC.book Seite 34 Montag, 27. September 2010 4:01 16
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Waeco COOLMATIC MDC 65K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Waeco COOLMATIC MDC 65K in the language / languages: Dutch, Danish, Swedish, Norwegian, Finnish as an attachment in your email.

The manual is 8,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Waeco COOLMATIC MDC 65K

Waeco COOLMATIC MDC 65K User Manual - English, German, French, Italian, Portuguese, Spanish - 108 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info