616437
28
Zoom out
Zoom in
Previous page
1/32
Next page
Troubleshooting COOLMATIC CR Series
50
Interior temperature too low in control level "1"
Compressor does not run (battery connection)
Fault Possible cause Remedy
Compressor runs con-
stantly
Faulty thermostat Change the thermostat
Compressor runs for a
long time
Large quantities have been frozen in
the freezer compartment
Fault Possible cause Remedy
U
KL
= 0 V There is an interruption in the connec-
tion between the battery and
the – electronics
Establish a connection
Main switch faulty (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
U
KL
U
EIN
Battery voltage is too low Charge the battery
Start attempt with
U
KL
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low Replace the battery
Cable cross section too small Replace the cable
(fig. e, page 9)
Start attempt with
U
KL
U
ON
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor Replace the compressor
U
KL
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
_cr-kuehlschraenke.book Seite 50 Montag, 6. April 2009 1:03 13
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Waeco Coolmatic CR-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Waeco Coolmatic CR-80 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info