819184
12
Zoom out
Zoom in
Previous page
1/148
Next page
EN
12 WWW.VONROC.COM
Setting the Automatic Shut-Off Pressure (Fig. E)
1. Press the pressure selector (21) on the controle
panel to switch between the different pressu-
re Units ( PSI, BAR, Kpa) until required unit is
displayed.
2. Press the “+”or “-“ on the controle panel until
the desired pressure shows on the display. By
holding the “+”or “-“ you can go up or down
quicker, release “+”or “-“at the dissured pressu-
re.
Note: After 3 seconds the display will flash and
return to areading of “0.0”. This is normal. The set
pressure will be remembered.
3. Move the mode selector I/0/II (20) into the
position ‘I’ to switch the appliance to start the
High pressure.
4. When the item to be inflated has reached the
preset valuepressure the unit will automatically
turn off.
Note: You may notice the actual pressure reading
may drop after acouple of seconds. This is normal.
5. To stop the inflator at any time, move the mode
selector I/0/II (20) into the position ‘O’ to switch
the appliance off.
Note: If the power switch is turned off, all settings
will be lost and will need to be reentered. This is
asafety feature to prevent the risk of items OVER
INFLATING.
Note: After afew minutes the machine is turned off
automatically. In order to switch on the machine,
press the Pressure selector (21) and the display
(28) will turn on.
Note: When using the Dunlop valve adapter, the
pressure gauge will not display an accurate value
due to characteristics of the valve. When inflating
atire, do not use the value on the pressure gauge,
but inflate it by checking the status of the tire. If
the tool stops before the tire reaches the desired
air pressure, adjust the pressure value, and then
inflate the tire again.
Note: When inflating afloating tube, the pressure
gauge will not display an accurate value since
the pressure of floating tube is less than 20 kPa
(3 PSI). When inflating afloating tube, do not use
the value on the pressure gauge, but inflate it by
checking the status of the floating tube.
Using the Inflator as aPressure Gauge
Note: This machine has amemory mode in pre-set
function.
Please make sure to switch machine off to remove
memory before using pressure gauge function.
1. In order to switch on the machine, press the Pres-
sure selector (21) and the display (28) will go on.
2. Reattach the hose connected to the valve to be
measured.
3. The digital readout will display the item’spressu-
re.
Removing the connection valve (Fig. D1, D2)
Removing with or without valve adapter: Open
the clamping lever (7) for the connection valve
(8) and remove from the valve and/or adapter of
the inflatable.
Remove any adapter and close the valve of the
inflated item (ball, inflatables or tyres)
Note: Air may escape from the valve of the infla-
table when removing the connection valve (8). Be
sure not to remove the connection valve (8) too
quickly. It may be necessary to add extra pressure
to the required pressure, to compensate for the
escaped air.
Storage high pressure hose and valve adapters
(Fig. F, G)
The high-pressure hose (9) is located in astorage
channel (10) on the back of the machine. Wrap
the high-pressure hose inside the channel.
The Valve adapters (14, 15, 16) are stored in the
back of the unit inside the valve adapter storage
(19).
LOW PRESSURE, HIGH VOLUME  INFLATA
BLES  SWITCH ‘II’
Inflating
Connecting the low pressure hose to the compressor
(Fig. H1)
1. Remove the low pressure hose (11) from the
storage (12).
2. Line up the notches (24) of the hose with the
nubs (23) of the low pressure inflator connection
(22) .
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vonroc S-CR503DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vonroc S-CR503DC in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 14.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info