778544
6
Zoom out
Zoom in
Previous page
1/64
Next page
6
EN
WWW.VONROC.COM
resulting in fire, explosion or risk of injury.
f)
Do not expose a battery pack or tool to fire
or excessive temperature. Exposure to fire or
temperature above 130 °C may cause explosion.
NOTE The temperature „130 °C“ can be replaced
by the temperature „265 °F“.
g)
Follow all charging instructions and do not
charge the battery pack or tool outside the
temperature range specified in the instructions.
Charging improperly or at temperatures outside
the specified range may damage the battery and
increase the risk of fire.
6) Service
a) Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the
power tool is maintained.
b)
Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
ADDITIONAL SAFETY WARNINGS FOR ROTARY
HAMMERS
a) Wear ear protectors. Exposure to noise can
cause hearing loss.
b) Use auxiliary handle(s), if supplied with the
tool. Loss of control can cause personal injury.
c) Hold power tool by insulated gripping surfaces,
when performing an operation where the cut-
ting accessory may contact hidden wiring or its
own cord. Cutting accessory contacting a “live”
wire may make exposed metal parts of the
power tool “live” and could give the operator an
electric shock.
Electrical safety
Always check that the voltage of the power
supply corresponds to the voltage on the
rating plate.
Do not use the machine if the mains cable or
the mains plug is damaged.
Only use extension cables that are suitable for
the power rating of the machine with a minimum
thickness of 1.5 mm
2
. If you use an extension
cable reel, always fully unroll the cable.
2. MACHINE INFORMATION
Intended use
This rotary hammer is intended for impact drilling
holes in masonry such as brick, concrete and similar
material. It is also suitable for drilling in wood, metal,
ceramic and plastic. Furthermore, the machine can
be used as a demolition hammer in combination
with the SDS cold chisels provided. The machine is
on no account intended for other purposes.
Not suitable for construction site usage.
TECHNICAL SPECIFICATIONS
Model No. RH505AC
Mains voltage 230 V ~
Mains frequency 50Hz
Power input 1800W
No-load speed 0-820 /min
Impact rate 0-4000 /min
Max. Drill diameter
- Concrete
- Steel
- Wood
Ø 36 mm
Ø 13 mm
Ø 42 mm
Weight 5.2 kg
Sound pressure (LPA) 94dB(A) K=3 dB(A)
Acoustic power (LWA) 105dB(A) K=3 dB(A)
Vibration
Hammer drilling concrete a
h,HD
19.190m/s K=1.5m/s
Chiseling a
h,Cheq
14.760m/s K=1.5m/s
Vibration level
The vibration emission level stated in this instruction
manual has been measured in accordance with a
standardized test given in EN60745; it may be used
to compare one tool with another and as a prelim-
inary assessment of exposure to vibration when
using the tool for the applications mentioned.
Using the tool for different applications, or with
different or poorly maintained accessories, may
significantly increase the exposure level.
The times when the tool is switched off or when
it is running but not actually doing the job, may
significantly reduce the exposure level.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vonroc RH505AC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vonroc RH505AC in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 6.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info