7. Product description
The multimeter (DMM) displays measurements on a digital display. The multimeter has 6000 counts (count = smallest
display value). The true RMS value is used when measuring voltages and currents. The correct socket assignment is
displayed according to the measurement mode selected. Incorrect socket assignment is indicated by a warning sound
and warning indicator. This increases the operational safety of the multimeter for the user.
If the DMM is not operated for approx. 15 minutes, the device switches off automatically. This saves battery power and
extends the period of operation. The automatic shut-off feature can be disabled manually.
The DMM can be used to take measurements up to CAT III 600 V. It is suitable for use in hobby and professional
applications.
Protective caps may be attached to the angled test lead plugs. Remove these before inserting the test leads into the
multimeter.
The DMM can be placed on a level surface using the fold-out stand for better readability.
With this multimeter, it is no longer necessary to replace a fuse that has accidentally tripped in the mA/µA measure-
mentrange.Thebuilt-inPTCprotectionelementslimitcurrentowintheeventofanoverloadandthusprotectthe
multimeter and the current circuit. The PTC protection elements reset themselves after tripping and a short cool-down
period.Forthis,thecurrentmeasurementcircuitmustonlybeinterruptedbriey.
The battery and fuse compartment can only be opened when all test leads have been removed from the multimeter.
When the battery and fuse compartment are open, the test leads cannot be inserted into the measurement sockets.
This is a built-in safety feature designed to protect the user.
Rotary control (D)
The individual measurement modes are selected via a rotary con-
trol. The automatic range selection “Auto” is active. This means
that the appropriate measurement range is set automatically. The
current measurement ranges must be set manually. Always start
current measurements with the largest measurement range, and
then switch to a smaller range if necessary.
The rotary control has a mode button (I). With the “SELECT” but-
ton, switch to a sub-mode if the measurement mode is double
assigned (e.g. switching resistance measuring for diode test and
continuity test or AC/DC switching). The sub-modes are marked
in grey. Press the “SELECT” button again to switch to the next
sub-mode.
To switch the multimeter off, move the rotary control to the “OFF” position. Always switch the multimeter off when it
is not in use.
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC276 TRMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC276 TRMS in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info