Error Possible cause Remedy
The multimeter Is the battery flat or is the high-cap Check the status. Change the battery or
doesn’t function (VC290) discharged? charge the device.
No measured Is the wrong measurement function Check the display (AC/DC)
value change. active (AC/DC)? measurement value change and switch
the function if necessary.
Did you use the wrong measuring Compare the connection with that shown
sockets? in the display.
Is the fuse defect? Check the fuses.
Is the Hold function activated in the Press the “H” button to deactivate this
VC290 (display "H") function.
ƽ
Repairs other than those described should only be carried out by an authorised
specialist. If you have queries about handling the measuring device, our technical
support is available under the following telephone number:
Voltcraft®, 92242 Hirschau, Lindenweg 15, Tel.-No. 0180 / 586 582 7.
Technical Data
Display 4000 Counts (digits), 2000 Counts for VC250
Measuring rate approx. 2-3 measuring operations/second
Measuring lead length approx. 90 cm each
Measuring impedance >10MΩ (V range)
Operating voltage 9V block battery (VC250/VC270)
High-cap/Solar cell (VC290)
Working conditions 0 to 30°C (<75%rF), >30 to 40°C (<50%rF)
Operating altitude max. 2,000 m
Storage temperature -10°C to +50°C
Weight approx. 380 g
Dimensions (LxWxH) 185 x 91 x 43 (mm)
Over-voltage category CAT III 600 V, Impurity level 2
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The
accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
75 %, non-condensing.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC270 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC270 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info