536149
44
Zoom out
Zoom in
Previous page
1/102
Next page
44
The Auto-Power-Off function can be manually deactivated.
To do so, turn the measuring device off (OFF). Keep the button “SELECT” pressed and turn the DMM
on at the dial switch. This function remains inactive until the measuring device is turned off via the dial
switch.
Cleaning and Maintenance
General Information
To ensure the accuracy of the multimeter over an extended period of time, it should be calibrated once
a year.
Apart from occasional cleaning and fuse replacements, the multimeter requires no servicing.
Information on changing the battery and fuse appears below.
ƽ
Regularly check the technical safety of the instrument and measuring lines, e.g.
check for damage to the housing or squashing etc.
Cleaning
Always observe the following safety instructions before cleaning the device:
ƽ
Live components may be exposed if covers are opened or parts are removed
(unless this can be done without tools).
The connected lines must be disconnected from the measuring device and all measuring objects prior
to cleaning or repairing the device. Switch the DMM off.
Do not use cleaning agents which contain carbon, petrol, alcohol or similar substances for cleaning
purposes. These could corrode the surface of the measuring instrument. The vapours are also detri-
mental to health and are explosive. Sharp-edged tools such as screwdrivers or metal brushes should
not be used for cleaning purposes.
For cleaning the device or the display and the measuring lines, use a clean, fuzz-free, antistatic slight-
ly damp cloth. Allow the product to dry completely before you use it again to conduct measurements.
Opening the Measuring Instrument
You can only change the fuses or battery if all measurement cables are disconnected from the mea-
suring device. The battery and fuse compartment (17) cannot be opened if measuring cables are con-
nected.
In addition, all of the measuring sockets are physically locked when the compartment is open, in order
to inhibit measuring cables being inserted. The locking mechanism is automatically deactivated if the
battery and fuse compartment is closed again.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC270 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC270 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info