738287
49
Zoom out
Zoom in
Previous page
1/112
Next page
49
13. Replacing the Fuse
Never operate the meter if the case is open. !DANGER TO LIFE!
1. Turn the function dial to the “OFF”
position.
2. Remove the test leads from the input
terminals.
3. Unscrew then remove the battery cover.
4. Unscrew the rear cover screws.
5. Replace the fuse with one that is of the
same type and specication. Refer to
the section “Technical data” for further
information.
6. Carefully replace the covers.
14. Troubleshooting
Problem Possbile cause Suggested solution
The DMM will not power up. Flat battery Replace with new battery.
Cannot measure changes
in value.
Is the wrong measuring function
activated (AC/DC)?
Check display (AC/DC) and switch the function
if required.
Are the incorrect leads used?
Check the terminal assignment or connection
of the probe leads.
Is the HOLD function activated? Deactivate the HOLD function.
No measurement possible
in the A measurement
range
Is the fuse of the A measuring
range defective?
Check the 10 A F2 fuse
No measurement possible
in the mA/µA measurement
range
Is the fuse of the mA/µA meas-
urement range defective?
Check the 0.6 A F1 fuse.
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC190 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC190 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 15,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info