Use a clean, lint-free, antistatic and slightly damp cloth to clean the device and display. Allow the
device to dry completely before using it for the next measuring task.
c) Opening the measuring device
For reasons of safety, it is only possible to replace the fuse and battery when all test leads have been
removed from the measuring device. The battery and fuse compartment cannot be opened when test
leads are plugged in.
In addition, when the housing is opened all measuring sockets are mechanically locked in order to
prevent the later insertion of the test leads. The locking will be automatically removed when the battery
and fuse compartment is again closed.
The housing is designed so that when the battery and fuse compartment is open only the battery
and fuses can be accessed. The housing does not have to be opened completely or taken apart any
longer. These measures increase the user safety and user-friendliness.
Proceed as follows to open:
1. Remove all test leads from the measuring device and switch
it off.
2. Loosen and remove the battery compartment screw (15) on
the back.
3. Fold out the positioning bracket (13). Pull the battery and
fuse compartment lid downwards from the measuring device
(Fig. 11).
4. The fuses and battery compartment are now accessible.
5. Close the housing in the reverse order and screw closed the
battery and fuse compartment.
6. The measuring device is again ready for use.
Fig. 11
97
mV Millivolt (=0,001 V)
V Volt (unité de tension électrique)
A Ampère (unité de l’intensité du courant)
mA Milliampère (=0,001 A)
µA Microampère (=0,000.001 A)
Hz Hertz (unité de fréquence)
kHz Kilohertz
MHz Megahertz
VA Voltampère (unité de puissance électrique apparente)
% Af chage en pourcentage pour la mesure de cycle de service
ºC Degré Celsius
ºF Degré Fahrenheit
Ohm (unité de résistance électrique)
k Kiloohm (=1.000 )
M Mégaohm (=1.000.000 )
nF Nanofarad (unité de capacité électrique = 0,000.000.001 F)
µF Microfarad (=0,000.001 F)
mF Millifarad (=0,001 F)
Symbole pour la plage de mesure de la capacité
Symbole d’avertissement en cas de tensions > 30 V/CA et > 42 V/CC
0 1 2 3 4 5 6
Af chage à barres du bargraphe (seulement pour V, A, )
Filtre passe-bas pour la tension alternative
Fonction Low Imp
9. PILE
Avant de pouvoir travailler avec l’appareil de mesure, vous devez d’abord insérer
la pile fournie.
a) Mise en place et remplacement de la pile
Pour son fonctionnement, l’appareil nécessite une pile monobloc alcaline de 9 V ou de lithium.
Lors de la première mise en marche ou lorsque le symbole de l’état de la pile (vide) apparaît
à l’écran, il faut remplacer la pile usagée par une pile neuve ou une batterie du même type. Tenez
également compte des consignes de sécurité concernant les piles / batteries (page 94).
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-890 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-890 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info