250 mV, 700 mV to approx. 3200 mV) will be measured provided
that the semiconductor path is not defective.
When the test probes are reversed, i.e. red to the cathode and
black to the anode, then the non-conducting direction of the se-
miconductor path is checked.
If "3,3V" is displayed, then the diode is in good condition. If, on
the other hand, a other voltage value is displayed, then either the
test object is connected incorrectly, or it is defective.
In addition, in the case of measured values < 100 mV, an acou-
stic signal sounds.
3. This acoustic signal sounds also during continuity tests on resi-
stors of less than 100 Ohm.
During diode or continuity testing, make sure that
the diode and any circuit into which it may possibly
be built is absolutely voltage-free. All capacitors
present must be discharged.
H Frequency measurement
The measuring instrument has a so-called AUTO RANGE feature
only with frequency measurement. This means that the measuring
range automatically adjusts to suit the connected frequency, reco-
gnisable by the position of the decimal point.
To measure a frequency, proceed as follows:
cordon
rouge
cordon
noir
Sense direct
cordon
rouge
cordon
noir
Sens bloqu
44
B Mise en service
Elément d'ajustage pour commutateur des fonctions de mesure ou
commutateur rotatif
Par l'intermédiaire du commutateur rotatif, l'appareil de mesure est
allumé et éteint (OFF).
La position du commutateur des fonctions de me-
sure ne doit en aucun cas être modifiée lors d'une
mesure, l'appareil de mesure pourrait en être
détruit (étincelle à rupture), respectivement pourra
présenter comme conséquence un danger de mort
lors de tensions supérieures à 25 VACrms ou 35
VDC
Ne dépassez jamais les valeurs maximales de me-
sure, car outre le risque d'endommager votre ap-
pareil, vous courez un danger de mort.
En disposition circulaire complète, les différentes mesures possi-
bles en partant de ("OFF" dans le sens des aiguilles d'une
montre)sont sélectionnables en tournant le commutateur :
DC= = Mesure du courant continu et de la tension continue
AC~ = Mesure du courant alternatif et de la tension alterna-
tive
kHz = Mesure de fréquences
+)/->I- = Contrôle de la circulation du courant électrique
(acoustique) et test des diodes
400ohms= Mesure de résistance
C Tenue de l'appareil pour l'utilisation
Tenez la transfo-pince de façon à ce que l'affichage à cristaux liqui-
61
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-605 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-605 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info