536348
38
Zoom out
Zoom in
Previous page
1/100
Next page
Only ever clamp one cable. If you clamp several cables, the currents
will cancel one another out and you will not get a measurement.
The permanent magnetism of the current sensor may lead to a small
current being shown in the display even when no cable is clamped. To
set the display to „0“ (DC-ZERO), press the REL button before mea-
suring (8).
b) Voltage-“V“/Frequency-“Hz“/ Duty Cycle „%“
measurement
Proceed as follows to measure voltages:
- Turn the meter on at the rotary switch and select measuring range „V/Hz“.
- Plug the red measuring lead into the V measuring socket (11) and the black mea-
suring lead into the COM measuring socket (10).
- With the Mode key (7) select whether you would like to measure direct (DC) - or
alternating current -(AC). The selected units will be shown in the display.
- Now connect the two measuring prods to the object to be measured (generator,
switching etc.).
- The measuring value is shown in the display. The AutoRange selection automat-
ically assigns the correct measuring range.
- After measuring, remove the measuring leads from the measuring object and
turn the meter off. Turn the rotary switch to „OFF“.
If a minus „-“ appears for the direct voltage in front of the measuring
value, the measured voltage is negative (or the measuring tips have
been mixed up).
Proceed as follows to measure frequencies or the duty cycle:
- Turn the meter on at the rotary switch and select measuring range „V/Hz“.
- Use the Hz% key (6) to select whether you wish to measure the frequencies „Hz“
or the Duty Cycle „%“ - the selected unit appears in the display.
- Connect the measuring leads to the measuring instrument in the same way as for
current measurement.
38
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-520 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info