536143
41
Zoom out
Zoom in
Previous page
1/106
Next page
b) Direct and alternating voltage measurement
ƽ
In no event exceed the max. permitted input values,
neither do it when measuring superposed direct vol-
tages (e.g. ripple voltages).
Proceed as follows to measure dc voltages:
• Turn the DMM on at the rotary
switch (1) and select the measu-
ring range „V“. The display shows
„DC“
• Now connect the two measuring
prods to the object to be measu-
red (battery, switching etc.).
• In the display (4), the polarity of
the measuring value concerned
will be indicated together with the
current measuring value.
For alternate current measuring, press the button „MODE“ (3) to
switch to the AC range. Pressing this button again, takes you back.
The voltage range „V DC/AC“ shows an input resistance of
>7.5 MOhm. As soon as a minus „-“ appears for the direct
voltage in front of the measuring value, the measured volta-
ge is negative (or the measuring tips have been mixed up).
41
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-10 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info