Connect the micro-USB connector (8) of the USB power meter to the USB power adapter, for
example. If necessary, use the provided USB cable.
If your USB-AC adapter has a cable with a micro-USB connector (such as the power supply
of a smartphone), you can plug it straight into the micro-USB connector (8) of the USB power
meter.
Alternatively, a USB port on a USB hub or a PC may be used as a source to supply voltage/
current.
Note that in any case the power consumption of the device used for measuring must not be
higher than what the power source (USB power adapter or the USB port of a USB hub or
computer) can deliver.
According to USB standard, a USB port on a USB 2.0/1.1 hub with power supply deliv-
ers a current of max. 500 mA. On the other hand, a USB port on a USB 2.0/1.1 hub
without power supply only delivers a current of max. 100 mA.
A modern USB 3.0 port of a computer or a USB 3.0 hub with power supply delivers
max. 900 mA. However, the output current of a notebook may also be less.
Beyond that, there are some USB ports that may deliver higher currents, such as the
USB charging port of a USB hub.
USB power supplies are available with an output current of 500 mA, 1 A, 2 A or more.
Therefore, please always follow the manual of the device which you are going to use as
a power supply. Do not overload the device!

The desired mode can be set using the sliding switch (3).
 
D Data connection/data transmission is possible
Use this mode for measuring the power consumption of a USB stick, a
USB hard drive or other USB devices. During the measuring process a
data transmission is possible (USB 2.0/1.1).
I Charging an Apple device (no data connection possible)
This mode is used to charge an Apple device (for example, an iPad
®
)
with a higher charging current.
S Charging an Android device (no data connection possible)
This mode is used to charge an Android device (for example, a smart-
phone or tablet) with a higher charging current.

Connect the device which you intend to measure to the USB power meters USB-A connector
(5). Use the provided USB cable, if necessary.

By repeatedly pressing button (4), you can select the desired indicator on the display (7).
LED “V” is on: The measured voltage is shown in the display.
LED “A” is on: The measured current is shown in the display.
“AU” will briey appear in the display: The measured voltage and the measured current are
then displayed alternately.

At excess voltage (> = 5.8 V), the display shows “SOS” and the LED
“V” goes on.
Never connect a device to the USB power meter when this is the
case; the high voltage can damage the device.
At excess current (> = 3 A), the display shows “SOS” and the LED “A”
goes on.
In such a case the attached device draws too much current, which
may damage the USB power meter. Disconnect the USB device from
the USB power meter.
The indicator automatically turns off after 8 minutes, if no changes in
current draw can be measured. Only the decimal point lights up.
Press button (4) to reactivate the display.
G




The USB power meter is used to measure and display voltage and current at a USB port. For
this purpose, the USB power meter is connected between the USB port (e.g., a USB power
adapter or a computer) and the USB device.
That way you are able to control the charging current and the voltage while loading a smart-
phone or a tablet computer for example.
Always observe the safety instructions and all other information included in these operating
instructions.
This product complies with the applicable national and European requirements. All names of
companies and products are the trademarks of the respective owners. All rights reserved.

USB power meter
USB cable
Operating instructions

An exclamation mark in a triangle indicates important instructions in this operating
manual which absolutely have to be observed.
The “arrow” symbol is used where special tips and notes on operation are provided.







The unauthorised conversion and/or modication of the product is not permitted
for safety and approval reasons (CE). Never dismantle the product.
The product is not a toy and does not belong in the hands of children.
Never overload the product. For more information about the admissible voltage/
current range, see the chapter “Technical data”.
The product must not be exposed to extreme temperatures, strong vibrations or
heavy mechanical stress. The product must not get damp or wet.
The manufacturer does not accept any liability for incorrect or inaccurate readings
or any consequences resulting from such readings.
Handle the product with care; it can be damaged by impacts, blows, or accidental
falls, even from a low height.
Do not leave packaging material carelessly lying around. It may become a dan-
gerous plaything for children!
If you are not sure about the correct operation or if questions arise which are not
covered by the operating instructions, please do not hesitate to contact our techni-
cal support or another specialist.

1 USB-A connector
2 Micro-USB connector
3 Sliding switch to select operating mode
4 Button to select display mode
5 USB-A connector (plug the measuring device in
here.)
6 LEDs for voltage (V) and current (A)
7 Display for measured value indication (voltage /
current)
8 Micro/USB jack
2
8
7
6
5
3
4
1

3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft PM-40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft PM-40 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info