Key Functionality
Moves the cursor from left to right.
Long press for speed.
Moves the cursor from right to left.
Long press for speed.
Scrolls upward the sequence of inserted digits.
Long press for speed.
Scrolls downward the sequence of inserted digits.
Long press for speed.
Places cursor to extreme right position of edit string
and shows the last 16 digits of edit string.
Reverts to previous or top menu without saving the
edit string.
Reverts to "<OK> TO EXIT" without saving the edit
string.
OK
I
Saves and reverts to previous menu.
Clears all digits to the right of cursor.
Clears one digit by cursor.
Selects between uppercase or lowercase digits.
PIN Code [Fig 4.5.2(7)]
Enter PIN code of the SIM card installed in the
PowerMaxExpress unit (up to 16 digits).
Force Home Network [Fig 4.5.2(8)]
Here you determine whether to force the SIM card to use
the home network only and not to select another network in
case the home network cannot be found.
The options are: disable and enable.
LAN Settings [Fig 4.5.2(9)]
Note: The LAN Settings menu appears only if a
Broadband Module exists in the PowerMaxExpress alarm
system.
Enable DHCP [Fig 4.5.2(9a)]
Here you determine whether to obtain an IP address
automatically using a DHCP server or to enter an IP
address manually.
Toggles between DHCP enable and DHCP disable.
Note: When DHCP is enabled, the last IP number will be
changed to 200. In other words, it will take the form
xxx.xxx.xxx.200.
Manual IP [Fig 4.5.2(9b)]
Here you manually enter LAN parameters.
IP address – the IP address of the Broadband Module.
Subnet mask – the subnet mask used with the IP
address.
Default GW – the default gateway of the Broadband Module.
Note: If DHCP is set to enabled the above entries will be
ignored.
Transport Protocol
(Applicable in the USA only)
[Fig 4.5.2(10)]
Here you select the type of protocol used by the control
panel to transfer data over the internet.
The options are: TCP and UDP.
Session Timeout [Fig 4.5.2(11)]
Here you determine whether the control panel will stay
continuously connected via GPRS communication, or,
temporarily connected to receive event reports only.
The options are: off on timeout and always ON.
4.5.3 C.S. Reporting (Fig. 4.5 Detail C)
Report Events [Fig 4.5.3(1)] – see note in Fig. 4.5 Detail C
Here you determine which types of event will be reported
to central stations. Due to lack of space in the display,
abbreviations are used: alarm is “alrm”, alert is “alrt” and
open/close is “o/c”. The asterisk (J) is a separator
between events reported to central station 1 and events
reported to central station 2.
Messages are divided by type into four groups:
No. Group Events Reported
1 Alarms Fire, Burglary, Panic, Tamper
2 Open/close Arming AWAY, Arming HOME,
Disarming
3 Alerts No-activity, Emergency, Latchkey,
Gas, Flood, Temperature
4 Maintenance Low-battery AC failure
"Alarm" group has the highest priority and "Alert" group
has the lowest priority.
The selectable options are as follows:
Plan name Sent to center 1 Sent to center 2
all -o/c J backup All but open/close
All but open/close if center 1
doesn’t respond
all J all All All
all-o/c J all -o/c All but open/close All but open/close
all –o/c J o/c All but open/close Open/close
all (–alrt) J alrt All but alerts Alerts
Alrm J all (–alrm) Alarms All but alarms
Disable report Nothing Nothing
all J backup All All if cent. 1 doesn’t respond
Note:All means that all 4 groups are reported and also
trouble messages - sensor / system low battery, sensor
inactivity, power failure, jamming, communication failure etc
.
1st Report Method [Fig 4.5.3(2)]
Here you define the 1st priority of method used to report
events. The options are: disable, broadband, cellular
and PSTN.
2nd Report Method [Fig 4.5.3(3)]
Here you define the 2
nd
priority of method used to report
events. If the method defined to report events in the 1st
priority fails, the control panel will attempt to report using
the method defined in the 2nd priority (see notes in 1
st
Report Method).
The options are: disable, broadband, cellular and PSTN.
3rd Report Method [Fig 4.5.3(4)]
Here you define the 3
rd
priority of method used to report
events. If the method defined to report events in the 2
nd
priority fails, the control panel will attempt to report using
the method defined in the 3rd priority (see notes in 1
st
Report Method).
The options are: disable, broadband, cellular and PSTN.
Dual Reporting [Fig 4.5.3(5)]
Here you determine whether to report events using PSTN
and cellular at the same time instead of waiting for the 1
st
method to fail before trying the 2
nd
method.
The options are: disable and PSTN & cellular, PSTN &
broadband and broadband & cellular.
Receiver 1 Account No. [Fig 4.5.3(6)] - see note in
Fig. 4.5 Detail C
Here you enter the number that will identify your specific
alarm control system to the 1
st
central station. The number
consists of 6 hexadecimal digits.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMax Express at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMax Express in the language / languages: English as an attachment in your email.

The manual is 3,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMax Express

Visonic PowerMax Express User Manual - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info