70 D-304829 PowerMaster-10/30 G2 User's Guide
PowerMaster-10 G2 PowerMaster-30 G2
(2) 7.2V 1300 mAh, rechargeable NiMH
battery pack, p/n 130AAM6BMX,
manufactured by GP or p/n LTT-
AA1300LSDX6B, manufactured by LTT.
(3) 9.6V 1800 mAh, rechargeable NiMH
battery pack, p/n GP180AAH8BMX,
manufactured by GP or p/n LTT-
AA1800LSDX8B, manufactured by LTT.
(4) 9.6V 2200 mAh, rechargeable NiMH
battery pack p/n 220AAH8BMX,
manufactured by GP or p/n LTT-
AA2200LSDX8B, manufactured by LTT.
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Notes:
1. For compliance with CE standards the battery
backup period must be at least 12 hours.
2. For compliance with UL standards the battery
backup period must be at least 24 hours.
Note: Only the LTT-AA2200LSDX8B battery
pack is approved for use by UL.
Time to Charge
80 % (
13 Hrs) 80 % (
30 Hrs) for all battery types
Optional Backup
Battery Pack
See "Backup Battery Options" above See "Backup Battery Options" table above
Time to Charge
(optional backup
battery pack)
80 % (
24 Hrs)
NA
Wired Detectors
Total (Sum)
Current
NA 36* mA max.
Site External Siren
Current (EXT)
NA 450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
Site Internal Siren
Current (INT)
NA 450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
*
Total PowerMaster-30 G2 output current
(of INT & EXT sirens, PGM output and
detectors) cannot exceed 550 mA.
PGM Current sink to control panel GND 100 mA
max.
Max. external DC voltage +30 VDC
Current sink to control panel GND 100 mA
max.
Max. external DC voltage +15 VDC
High Current /
Short Circuit
Protection
NA All outputs are protected (automatic reset fuse)
E4. Communication
PowerMaster-10 G2 PowerMaster-30 G2
Communication PSTN; GSM; GPRS; IP (for future use) PSTN; GSM; GPRS; IP (for future use)
Built-in Modem 300 baud, Bell 103 protocol 300 baud, Bell 103 protocol
Data Transfer to
Local Computer
Via RS232 serial port Via RS232 serial port
Report
Destinations
2 Monitoring Stations, 4 private telephones 2 Monitoring Stations, 4 private telephones
Reporting Format
Options
SIA, Contact ID, Scancom, SIA IP, Visonic
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
SIA, Contact ID, Scancom, SIA IP, Visonic
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
Pulse Rate 10, 20, 33 and 40 pps - programmable 10, 20, 33 and 40 pps - programmable
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info