580332
22
Zoom out
Zoom in
Previous page
1/74
Next page
MENUS AND FUNCTIONS
D-304829 PowerMaster-10/30 G2 User's Guide 21
C. User Settings Options Menu
Click until the display reads the desired setting option and then press .
SET ZONE BYPASS
Use to set the Zone Bypass Scheme i.e. to bypass (exclude) faulty or unsecured
("disturbed") zones, or to clear a bypassed zone (unbypass). For further details and
programming procedure see section B.1.
3
REVIEW BYPASS
Use to quickly review the Bypass Scheme i.e. which zones are bypassed. For
further details and reviewing procedure see section B.2.
3
RECALL BYPASS
Use to Recall the last used bypassed scheme for reuse in next arming period. For
further details and recalling procedure see section B.3.
3
USER CODES
Use to program your Master User secret access code and the seven codes of the
other users. For further details and programming procedure see section B.4.
DURESS CODE
*
Use to program the Duress (ambush) code. For further details and programming
procedure see section B.5.
PROXIMITY TAGS
Use to add new Proximity Tags to or to delete Proximity Tags when lost. For further
details and programming procedure see section B.6.
KEYFOBS
Use to add new Keyfob Transmitters or to delete Keyfob Transmitters when lost.
For further details and programming procedure see section B.7.
TIME & FORMAT
Use to set the time clock to show the correct time and time format. For further
details and programming procedure see section B.8.
DATE & FORMAT
Use to set the calendar date to show the correct date and date format. For further
details and programming procedure see section B.9.
AUTO-ARM ENABLE
Use to enable or disable the Automatic Daily Arming option at predefined times
(see Auto-Arm Time setting). For further details and programming procedure see
section B.10.
AUTO-ARM TIME
Use to set the predetermined time for the Automatic Daily Arming if enabled (see
Auto-Arm Enable setting). For further details and programming procedure see
section B.11.
PRIVATE REPORT
Use to program the four private telephone numbers for reporting alarm and other
event messages to private subscribers. For further details and programming
procedure see section B.12.
SQUAWK
Use to enable or disable the squawk sound i.e. arm / disarm feedback indication.
For further details and programming procedure see section B.13.
SCHEDULER
Use to set the daily / weekly time schedule for start & stop activation of devices
connected to the PGM output. For further details and programming procedure see
section B.14.
VOLUME CONTROL
Use to adjust the volume level of the various system beeps, chime signal and voice
prompts, and to enable or disable the Voice option. For further details and
programming procedure see section B.15.
SERIAL NUMBER
Use to read the system serial number and similar data
see section B.16.
<OK> TO EXIT
Use to exit from the “USER SETTINGS” menu back to Main Menu. For further
details see section A.2.
Returns to
first option
*
Duress Code is not applicable for UL installations
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info