813781
31
Zoom out
Zoom in
Previous page
1/112
Next page
31
To switch off central heating for a heating/cooling cir-
cuit, select the "Only DHW" or "Standby mode"
operating program.
For the preferred heating/cooling circuit
1. Standard menu:
/ for the operating program:
"Only DHW" (no central heating/cooling)
or
"Standby mode" (frost protection active)
2. OK to confirm
For all heating/cooling circuits
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit
4. "Operating program"
5. "Only DHW" (no central heating/cooling)
or
"Standby mode" (frost protection active)
For information on the operating programs, see
page 21.
Temporarily adjusting the room temperature
If you wish to adjust the room temperature temporarily,
select "Party mode". "Party mode" is independent
of the time program for central heating/central cooling.
For central heating, the home is heated to the tem-
perature set for "Party mode".
For central cooling, the home is cooled to the tem-
perature set for "Party mode".
If your contractor has not made alternative adjust-
ments, DHW is heated to the selected DHW temper-
ature first, before central heating/central cooling
commences.
The DHW circulation pump is switched on (if instal-
led).
Setting Party mode for central heating/central cooling
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit
Note
"Party mode" cannot be set for a separate cool-
ing circuit.
4. "Party mode"
5. Set the required room temperature for "Party
mode".
Party mode
Change with (
HC1
23°C
Fig. 15
Note
In conjunction with a ventilation unit:
Set the room temperature for ventilation max. 4 °C
lower than for "Party mode". This setting will
ensure that the bypass functions correctly.
Central heating/central cooling
Stopping central heating/central cooling
5817913
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOTRONIC 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOTRONIC 200 in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOTRONIC 200

Viessmann VITOTRONIC 200 User Manual - German - 112 pages

Viessmann VITOTRONIC 200 User Manual - Dutch - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info