External hook-up
Your contractor has connected external switching
contacts to your heat pump control unit and set their
functions. With these switching contacts, the heat
pump or particular system components such as a
mixer can be switched on or off.
or
Your contractor has integrated the heat pump into a
building management system. This system switches
particular functions, system components or operating
programs on or off, regardless of your settings.
Note
While "External hook-up" is active, you cannot
change the set operating program on the heat pump
control unit. Once "External hook-up" has ended, the
heat pump control unit continues using the previously
set operating program.
External program
Your contractor has connected the heat pump control
unit to the internet, e.g. via the Vitoconnect internet
interface.
The operating program and other functions are
switched on or off via a Viessmann app.
Note
While "External program" is active, you can change
the set operating program on the heat pump control
unit after responding to a prompt. Once "External
program" has ended, the heat pump control unit con-
tinues using the previously set operating program.
Holiday program
See page 33.
Procedure for setting a time program
The following explains how to enter the settings for a
time program. The specifics of the individual time pro-
grams can be found in the relevant chapters.
You can set up a time program for the following func-
tions:
Central heating/central cooling: See page 27.
Heating a buffer cylinder: See page 28.
Cooling a buffer cylinder: See page 29.
DHW heating: See page 35.
DHW circulation pump: See page 37.
Electric booster heater: See page 39.
Quieter operation of air/water heat pumps: See
page 41.
Mechanical ventilation (in conjunction with ventilation
unit): See page 44.
The time program allows you to divide the day into
sections. These are called time phases. It is for you to
decide what happens in these time phases, e.g.
whether your rooms should be heated to the standard
room temperature. For this, set an operating status
for each time phase.
The available operating statuses differ, e.g. through
different temperature levels.
You can set the time program individually, to be the
same, or different, for every day of the week.
You can select up to 8 time phases per day.
The time phases are numbered.
For each time phase you set the start and end
points.
The selected time phase is illustrated by a white bar
on the time chart. The length of the bar reflects the
length of time.
The individual operating status is indicated on the
time chart by bars of different heights.
Where several time phases overlap, the operating
status with the highest bar takes priority.
In the extended menu, you can call up the time pro-
grams under "Information": See page 53.
Setting a time program using central heating/central cooling as an example
1. Extended menu:
2. "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit.
4. "Time proghtg/cooling"
5. Select part of the week or a day.
6. Select a time phase ! to (. The selected time
phase is illustrated by a white bar on the time
chart.
7. Set the start and end points for the relevant time
phase. The length of the white bar on the time
chart is adjusted accordingly.
Operating the heat pump control unit
Operating program information (cont.)
5817913
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitotronic 200 - WO1C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitotronic 200 - WO1C in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitotronic 200 - WO1C

Viessmann Vitotronic 200 - WO1C User Manual - German - 112 pages

Viessmann Vitotronic 200 - WO1C User Manual - Dutch - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info