813832
36
Zoom out
Zoom in
Previous page
1/60
Next page
36
Cause Remedy
The heating system is switched off. Turn on the ON/OFF switch (see page 34).
Switch ON the mains isolator if installed (outside the
boiler room).
Set the MCB in the power distribution board (main do-
mestic MCB).
Control unit incorrectly adjusted.
The remote control (if installed) is set incorrectly.
Separate operating instructions
Central heating must be set.
Check the settings and correct if required:
Operating program (see page 15)
Room temperature (see page 20)
Time (see page 27)
Time program, central heating (see page 21)
Heating curve (see page 21)
The DHW cylinder is being heated. Wait until the DHW cylinder has been heated up.
Reduce the DHW draw-off rate or temporarily reduce
the DHW temperature as required.
No fuel. With oil or LPG:
Check the fuel reserves and re-order if required.
With natural gas:
Open the gas shut-off valve. If necessary, check with
your gas supply utility.
"Fault" is displayed. Check what type of fault it is. Acknowledge the fault
(see page 31). If necessary, notify your contractor.
"Burner fault" is displayed. Vitotronic 200, type CO1E:
Press the burner reset button.
See separate boiler or burner instructions.
Vitotronic 200, type CO1I:
Follow the instructions on the display: See page 32.
Contact your contractor if the burner still fails to start.
Danger
If faults are not rectified, they can have life
threatening consequences.
Do not acknowledge fault messages several
times in quick succession. Notify your contractor
if a fault recurs. Your contractor will be able to
analyse the cause and rectify the fault.
"Screed drying" is activated. No action required.
The set operating program will be enabled once the
screed drying time has elapsed.
The mixer motor is faulty. Notify your heating contractor.
"External hook-up" enabled. No action required.
The operating program set at the control unit was e.g.
changed over via an externally connected button.
Example: In a school, heating demand exists outside of
school times, e.g. for a parents’ evening.
This function cannot be influenced via the control unit.
Once the external changeover no longer applies, the
set operating program becomes active again.
"External program" activated. The operating program set at the control unit has been
changed by another control device.
You can change the operating program on the Vitotron-
ic control unit.
What to do if...
Rooms are too cold
5863724
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitotronic 200 - CO1E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitotronic 200 - CO1E in the language / languages: English as an attachment in your email.

The manual is 2.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitotronic 200 - CO1E

Viessmann Vitotronic 200 - CO1E User Manual - German - 64 pages

Viessmann Vitotronic 200 - CO1E User Manual - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info