You can set up a time program for the following functions:
Function Setting options Function
Within the time phase Outside the time phase
Room heating/cool-
ing
(separately adjusta-
ble for each heating/
cooling circuit)
Remote control
Control unit of the
Viessmann appli-
ance
Your rooms are tempered to the
selected temperature level:
"Comfort"
"Normal"
Your rooms are tempered to the
reduced room temperature.
DHW heating Remote control
Control unit of the
Viessmann appli-
ance
DHW heating is switched on.
The water in the DHW cylinder
is heated to the set DHW tem-
perature.
Domestic hot water heating is
switched off.
DHW circulation
pump
Heat generator con-
trol unit
The DHW circulation pump is
switched on.
The DHW circulation pump is
switched off.
Only if the ventilation unit is being operated without a Viessmann appliance:
Ventilation Remote control
Four-stage push-
button
ViCare app
Your rooms are ventilated at the
selected ventilation level:
"Stage 3"
"Stage 2"
Note
If the operating program is
"Time program" with sensor
priority, the ventilation level is
adjusted automatically if the air
quality demands it.
Your rooms are ventilated to
ventilation stage 1.
Note
If the operating program is
"Time program" with sensor pri-
ority, the ventilation level is ad-
justed automatically if the air
quality demands it.
The time programs can be set individually to be the
same, or different, for every day of the week.
Setting time phases
The procedure is explained using the example of room
heating for heating/cooling circuit 1 in weather-com-
pensated mode.
You can set up to 4 time phases in each "Time pro-
gram".
For each time phase, you define the start point "Start"
and the end point "End".
Example:
"Time program" for the weekday "Monday" for
"Heating/cooling circuit 1"
Time phase 1:
06:30 to 12:00 h with standard room temperature
Time phase 2:
15:00 to 20:00 h with comfort room temperature
In between these time phases the system heats to a
reduced temperature.
Tap the following on-screen buttons:
1. for the required heating/cooling circuit
2. for approx. 2 seconds.
The menu for the heating/cooling circuit is dis-
played.
3. for "Time program"
4. to confirm
5. for the required day or a group of days
6. to confirm.
A clock face with 24-hour view is displayed.
Meaning of the colour markings:
Blue Intervals between the set time phases,
"Reduced" temperature level
Yellow Set time phase with "Normal" tempera-
ture level
Orange Set time phase with "Comfort" tempera-
ture level
Changing time phase 1:
01. to select the required time phase
Using the remote control
Procedure for setting a time program (cont.)
5839615
Operation
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitotrol 300-E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitotrol 300-E in the language / languages: English as an attachment in your email.

The manual is 3.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitotrol 300-E

Viessmann Vitotrol 300-E User Manual - German - 64 pages

Viessmann Vitotrol 300-E User Manual - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info