Underfloor heating
Underfloor heating systems are slow, low temperature
heating systems that respond only very slowly to short
term temperature changes.
Heating with reduced room temperature at night there-
fore does not result in any significant energy savings.
Heating mode
Operating modes
To heat your home, the heat generator provides heat
as specified by the set flow temperature. The operating
mode determines whether the flow temperature is
specified with a fixed value or whether it is automati-
cally calculated and adjusted subject to several ancil-
lary conditions.
Your contractor can configure the following operating
modes during commissioning:
Weather-compensated operation
Continuous operation
Room temperature-dependent operation
Comfort mode
For periods when you are at home during the day, heat
your home with the comfort room temperature or the
comfort flow temperature, depending on the operating
mode. Set the periods (time phases) with the "Com-
fort" temperature level using the time program for cen-
tral heating.
Continuous operation
In continuous operation the heat generator provides
heating water with a constant flow temperature regard-
less of the outside temperature.
With this operating mode, you can operate several
heating circuits via your control unit.
Standard heating mode
For periods when you are at home during the day, heat
your home with the normal room temperature or the
normal flow temperature, depending on the operating
mode. Set the periods (time phases) with the "Stand-
ard" temperature level using the time program for cen-
tral heating.
Room temperature-dependent heating operation
In room temperature-dependent operation a room is
heated until the set room temperature has been
reached. For this, a separate temperature sensor must
be installed in the room.
The heating output is controlled independently of the
outside temperature.
With this operating mode, you can operate one heating
circuit via your control unit. You can input some of the
settings for this heating circuit at your room tempera-
ture controller.
Reduced heating operation
For periods when you will be absent or during the
night, heat your rooms with the reduced room temper-
ature or the reduced flow temperature, depending on
the operating mode. Set the periods (time phases) with
the "Reduced" temperature level using the time pro-
gram for central heating.
With underfloor heating systems, reduced heating
operation only yields limited energy savings (see
"Underfloor heating system").
Weather-compensated heating operation
In weather-compensated operation, the flow tempera-
ture is controlled according to the outside temperature.
More heat is made available at a lower outside temper-
ature than at a higher one.
The outside temperature is captured and transmitted to
the control unit by a sensor fitted outside the building.
With this operating mode, you can operate several
heating circuits via your control unit. If remote control
units are installed in your rooms, you can also adjust
the settings at the remote control units.
Heating curve
Heating curves illustrate the relationship between the
outside temperature, the set room temperature and the
flow temperature. The lower the outside temperature,
the higher the flow temperature.
In order to guarantee sufficient heat with minimum
energy consumption at any outside temperature, the
conditions of your building and system must be taken
into consideration. The heating curve is adjusted by
your contractor for this purpose.
Appendix
Terminology (cont.)
5593212
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitodens 222-F - 2023 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitodens 222-F - 2023 in the language / languages: English as an attachment in your email.

The manual is 3.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitodens 222-F - 2023

Viessmann Vitodens 222-F - 2023 User Manual - German - 68 pages

Viessmann Vitodens 222-F - 2023 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info