813674
10
Zoom out
Zoom in
Previous page
1/44
Next page
10
The appliance is intended solely for installation and
operation in sealed unvented heating systems that
comply with EN 12828, with due attention paid to
CECS 215-2017 and the associated installation, serv-
ice and operating instructions. It is only designed for
heating up heating water that is of potable water qual-
ity.
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific compo-
nents has been carried out.
The appliance is intended exclusively for domestic or
semi-domestic use; even users who have not had any
instruction are able to operate the appliance safely.
Commercial or industrial usage for a purpose other
than heating the building or DHW shall be deemed
inappropriate.
Any usage beyond this must be approved by the man-
ufacturer in each individual case.
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and will result in an exclusion of liability. Incorrect
usage also occurs if the components in the heating
system are modified from their intended use (e.g. if the
flue gas and ventilation air paths are sealed).
Product information
The control unit is a boiler and heating circuit control
unit for the following operating modes:
Weather-compensated operation
Constant operation with time program
Room temperature-dependent operation:
Constant operation as option with room tempera-
ture controller
OpenTherm controller
Individual room control with/without modulation
Your heating contractor will configure the operating
mode during commissioning in accordance with your
heating system.
These instructions describe all 4 operating modes.
The setting options for room temperature-dependent
operation with an OpenTherm controller via the system
are limited:
OpenTherm controller operating instructions
Weather-compensated operation
In weather-compensated operation, the flow tempera-
ture level is controlled according to the outside temper-
ature. The lower the outside temperature, the higher
the flow temperature. This means that more heat is
provided for central heating on cold days than on
warmer days.
In weather-compensated operation, 1 heating circuit
without mixer and 1 heating circuit with mixer can be
operated with the control unit.
Constant operation with time program
In constant operation, the heat generator provides
heating water with a constant flow temperature regard-
less of the outside temperature.
Heating times are controlled by a time program.
In constant operation, 1 heating circuit without mixer
and 1 heating circuit with mixer can be operated with
the control unit.
Room temperature-dependent operation
In room temperature-dependent operation, the central
heating is switched on or off subject to the room tem-
perature. The flow temperature remains constant.
In room temperature-dependent operation, 1 heating
circuit without mixer can be operated with the control
unit.
Constant operation as option with room tempera-
ture controller
In constant mode with a room temperature controller,
the controller measures the room temperature and
compares it with the selected required room tempera-
ture. If the temperatures are different, the room tem-
perature is regulated to the required value.
Introductory information
Intended use
6167584
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitodens 111-W - 2023 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitodens 111-W - 2023 in the language / languages: English as an attachment in your email.

The manual is 1.96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitodens 111-W - 2023

Viessmann Vitodens 111-W - 2023 User Manual - German - 44 pages

Viessmann Vitodens 111-W - 2023 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info