5
For your Safety (continued)
H Carbon monoxide
The U.S. Consumer Product Safety
Commission strongly recommends the
installation of carbon monoxide
detectors in buildings in which
gas-burning equipment is installed.
Carbon monoxide (CO) is a colorless,
odorless gas, which may be produced
during incomplete combustion of fuel
and/or when the flame does not receive
an adequate supply of combustion air.
Carbon monoxide can cause severe
personal injury or loss of life.
Therefore, carbon monoxide detectors
that are in compliance with a nationally
recognized standard (e.g. ANSI/UL
2034-2002, CSA 6.19-01) should be
installed and maintained in buildings that
contain gas-burning equipment.
Note:
Viessmann does not test any detectors
and makes no representation regarding
any brand or type of detector.
H For safe operation
We recommend that you frequently:
- Check for debris which could obstruct
the flow of flue gases. The vent or
chimney must not be blocked. A
blocked or partially blocked vent or
chimney can cause flue gases to leak
into the structure. Flue gases leaking
into the house can cause injury or
death. A qualified heating contractor
must remove the blockage from
blocked or partially blocked chimneys.
- Check pressure gage for correct
system (water) pressure. Check for
water on the floor from the discharge
pipe of the pressure relief valve or any
other pipe, pipe joint, valve or air
vent.
- Check for moisture, water, or
appearance of rust on the flue gas
pipes, their joints as well as vent
dampers, or side wall vent terminals
(if so equipped).
- Ensure that nothing is obstructing the
flow of combustion and ventilation air
and no chemicals, garbage, gasoline,
combustible materials, flammable
vapors and liquids are stored (not
even temporarily) in the vicinity of the
boiler.
-Donot allow unsupervised children
near the boiler.
Service/inspection of the boiler and the
system is recommended once per year.
Maintenance, service and cleaning are
specified in the Installation and Service
Instructions.
Before the heating season begins, it is
recommended that the boiler and burner
be serviced by a qualified heating
contractor. Service contracts may be
established through gas suppliers or
other licensed contractors in your area.
5581 532 v1.1
As there are no user-serviceable parts
on the boiler, burner or control, the
end-user must not perform service
activities or adjustments of any kind on
system components. Failure to heed
this warning can cause property
damage, severe personal injury, or loss
of life.
WARNING
Improper installation, adjustment,
service, or maintenance can cause flue
products to flow into living space. Flue
products contain poisonous carbon
monoxide gas which can cause nausea
or asphyxiation resulting in severe
personal injury or loss of life.
WARNING
Should overheating occur or the gas
supply fail to shut off, do not
disconnect the electrical supply to the
pump. Instead, shut off the gas supply
at a location external to the appliance.
CAUTION
The operator/ultimate owner is required
to have the heating boiler, burners, and
controls checked, as a minimum once
per year, by the original installer or by a
competent heating contractor familiar
with the equipment. Defects must be
corrected immediately.
WARNING
Do not use this boiler if any part has
been under water. Immediately call a
qualified heating contractor to inspect
the boiler and to replace any part of the
control system and any gas control
which has been under water.
CAUTION
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitodens 100-W WB1A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitodens 100-W WB1A in the language / languages: English as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitodens 100-W WB1A

Viessmann Vitodens 100-W WB1A Installation Guide - English - 104 pages

Viessmann Vitodens 100-W WB1A User Manual - Dutch - 20 pages

Viessmann Vitodens 100-W WB1A Installation Guide - Dutch - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info