5813 312 - 02
Vitocell 300-W/V, EVIA/EVIB Installation, Operating and Service Operation
Domestic Hot Water Production
Ensure the instructions and requirements
of the boiler control and system accessories
are observed.
Domestic hot water production can occur via heating
boiler, a remote heating plant or low temperature heating
via bivalent operation.
The maximum heating supply temperature is 320°F
(160°C), the maximum operating pressure is 150 psig on
the tank.
Domestic hot water production
1. Set the desired domestic hot water temperature
(140°F (60°C) for example) on the operating control
of the heating system.
2. The supply temperature for domestic hot water
production is set on the heating system operating
control. It should be approximately 27°F (15°C)
above the desired domestic hot water temperature.
3. For your personal safety, we recommend the
installation of a tempering valve to restrict the entry
of excessively hot domestic hot water into the system.
Hire a qualified heating contractor.
IMPORTANT
Domestic hot water may be preheated or heated to
temperatures over 113°F (45°C) depending on system
energy output and temperature characteristics.
WARNING
Domestic hot water temperatures over 125°F (52°C)
can cause severe burns instantly or death from scalds.
Children, disabled and elderly are at highest risk of being
scalded. Feel water before bathing or showering.
Temperature limiting valves are available and must be
used where domestic hot water storage tank temperature
exceed 140°F (60°C).
Initial Start-up
1. Fill tank with domestic drinking water.
2. Check heating side and domestic water side adaptors
for leaks. Tighten if necessary.
3. Ensure that DHW tank temperature sensor is properly
inserted into the mounting clamp.
4. Verify proper operation of temperature and pressure
relief valve (T&P valve).
5. Activate power supply.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitocell 300-V EVIA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitocell 300-V EVIA in the language / languages: English as an attachment in your email.

The manual is 1.24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitocell 300-V EVIA

Viessmann Vitocell 300-V EVIA Usermanual and installation guide - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info