Switching low-noise mode on/off
In quieter operation, the speeds of the fan and, if
appropriate, the compressor are reduced. This
reduces the sound level from operating the outdoor
unit.
Tap the following buttons:
1.
2. "Extended menu"
3. "Low-noise mode"
4. "Switch on/off"
5. "ON" if you want to start low-noise mode.
"OFF" if you want to stop low-noise mode.
Heat pump cascade
If you are using a heat pump cascade, you can carry
out the settings for low-noise mode only on the lead
heat pump.
Setting the time program for quieter operation
In the time program for quieter operation, set the time
phases in which the speed of the fan and, if required,
of the compressor are limited.
To do so, select an operating status for each time
phase: See chapter "Operating status for quieter oper-
ation".
Factory setting: No time phase from 00:00 to 24:00 h
for every day of the week. The fan speed is not limited.
Tap the following buttons:
1.
2. "Extended menu"
3. "Low-noise mode"
4. "Time program"
5. Set the required time phases and operating status.
to change the time phase
for a new time phase
to delete a time phase.
to select the time phase if more than one
time phase is set.
Note
The fan speed is not limited between the set time
phases.
If is not displayed, your contractor has locked the
setting for low-noise mode. Your contractor can
unlock the controls. You can check a time program
set by the contractor for quieter operation under
"Information".
For how to set a time program: See page 22.
Operating status for quieter operation
You can choose between 2 operating statuses: "Slight"
The max. fan speed and, if required, that of the com-
pressor are reduced by a small amount.
"Significant"
The max. fan speed and, if required, that of the com-
pressor are reduced by a large amount.
Switching emergency mode on/off
In emergency mode, the outdoor unit is switched off.
Room heating and DHW heating are provided by the
electric booster heater (instantaneous heating water
heater). If an external heat generator is connected, this
will take over the room heating.
In emergency mode, room cooling is switched off.
Tap the following buttons:
1.
2. "Extended menu"
3. "Emergency mode"
4. "ON" if you want to start emergency mode.
"OFF" if you want to stop emergency mode.
Heat pump cascade
If you are using a heat pump cascade, you must switch
on emergency mode on each heat pump separately.
Advanced
Quieter operation
6199646
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOCAL 252-A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOCAL 252-A in the language / languages: English as an attachment in your email.

The manual is 4.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOCAL 252-A

Viessmann VITOCAL 252-A User Manual - German - 80 pages

Viessmann VITOCAL 252-A User Manual - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info