813784
54
Zoom out
Zoom in
Previous page
1/72
Next page
54
Clean the surface of the programming unit with a
microfibre cloth.
!Please note
Commercially available domestic cleaning
agents and special cleaning agents for the heat
exchanger (evaporator) can damage the indoor
and outdoor units.
Clean the appliance surfaces only with a damp
cloth.
If necessary, clean the heat exchanger (evap-
orator) fins on the back of the outdoor unit only
with a hand brush with long bristles.
Danger
The sharp edges of the heat exchanger (evapo-
rator) fins can cause cut injuries.
Do not touch the fins on the back of the outdoor
unit.
Danger
The hot or cold fins of the heat exchanger
(evaporator) can cause burn or frostbite injuries.
Do not touch the fins on the back of the outdoor
unit.
!Please note
Commercially available cleaning agents can
damage the surface of the external casing.
Use only mild water-based domestic cleaning
agents.
Do not use substances containing acids or
solvents, such as vinegar-based cleaners,
nitro or synthetic resin solutions, nail varnish
remover, ethyl alcohol, etc.
!Please note
Mechanical impact will scratch the surface of the
external casing.
Wipe the surface with a soft damp cloth only.
Do not use substances that contain abrasive
particles such as polishes, scouring agents,
dirt erasers or scouring pads.
Do not clean the external casing with a pres-
sure washer.
Inspection and maintenance
The inspection and maintenance of a heating system
is prescribed by the German Buildings Energy Act and
the DIN 4755, DVGW-TRGI 2018, DIN 1988-8 and
EN 806 standards.
Regular maintenance ensures trouble-free, energy effi-
cient, environmentally responsible and secure heating
and cooling operation. For this, it is best to arrange an
inspection and maintenance contract with your local
contractor.
Note
Your outdoor unit contains highly flammable refrigerant
of safety group A3. To ensure operational reliability
over the entire service life of the heat pump, there are
special requirements for inspection and maintenance.
A special test of safety equipment is required after
12 years. Please contact your contractor.
DHW cylinder
Standard EN 806-5 specifies that maintenance and
cleaning should be carried out no later than 2 years
after commissioning and as required thereafter.
Only a qualified contractor should clean the inside of
the DHW cylinder and the DHW connections.
If any water treatment equipment (e.g. a sluice or
injection system) is installed in the cold water supply of
the DHW cylinder, ensure this is refilled in good time.
For this, observe the manufacturer's instructions.
Safety valve (DHW cylinder)
The function of the safety valve must be checked
every six months by the user or a contractor through
venting (see valve manufacturer's instructions). The
valve seat may become contaminated.
Water may drip from the safety valve during a heat-up
process. The outlet is open to the atmosphere.
!Please note
Overpressure can cause damage.
Do not close the safety valve.
Maintenance
Cleaning
6199646
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOCAL 250-A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOCAL 250-A in the language / languages: English as an attachment in your email.

The manual is 4.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOCAL 250-A

Viessmann VITOCAL 250-A User Manual - German - 80 pages

Viessmann VITOCAL 250-A User Manual - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info