813863
18
Zoom out
Zoom in
Previous page
1/28
Next page
18
,
A
D
C
E
B
Fig. 16
ALED 7 status
BLED 8 heat demand
CLEDs 1 to 6 heating circuits
DPushbutton T1 pairing
EPushbutton T2 reset
Key to LEDs
Colour/status of the LEDs Meaning
LED 1 to LED 6
Off No actuator for heating circuit detected.
"Normally closed" actuator:
Output is not supplied with power.
"Normally open" actuator:
Output is supplied with power.
Illuminates green. Actuator for heating circuit detected.
"Normally closed" actuator:
Output is supplied with power.
"Normally open" actuator:
Output is not supplied with power.
Illuminates orange. Actuator for heating circuit detected. Set temperature is lower than the actual
temperature.
"Normally closed" actuator:
Output is not supplied with power.
"Normally open" actuator:
Output is supplied with power.
Illuminates red. Short circuit or overload for the actuator detected. The actuator is no longer
being controlled.
"Normally closed" actuator:
Output is not supplied with power.
"Normally open" actuator:
Output is supplied with power.
Remedy
Check connection of flow temperature sensor: See page 16.
Check connection of actuator, see page 15:
230 V actuators must be used.
S1 to brown and S2 to blue always in the same zone.
Check connection of antenna: See page 17.
The floor thermostat's standard plug must be plugged in. 230 V must be
present.
Commissioning
Display and controls
6152540
Commissioning
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann ViCare floor thermostat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann ViCare floor thermostat in the language / languages: English as an attachment in your email.

The manual is 3.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info