The ViCare floor thermostat is designed exclusively for
operation in residential or commercial buildings. Incor-
rect use of the device (e.g. commercial or industrial
use other than for control purposes) is prohibited and
will result in an exclusion of liability.
Installation, service and operating instructions included
with the product and available online must be
observed. Use the ViCare floor thermostat exclusively
for monitoring, operating and optimising systems with
the user interfaces and communication interfaces
specified for this purpose in the relevant printed docu-
mentation. With regard to the communication interfa-
ces, ensure on site that the system requirements
specified in the product documentation are met at all
times for every transfer medium employed.
Note
The device is intended exclusively for domestic or
semi-domestic use, i.e. even users who have not had
any instruction are able to operate the device safely.
Product information
The ViCare floor thermostat enables intelligent control
of the underfloor heating system with up to 6 heating
zones and 18 thermal actuators.
The ViCare floor thermostat can only be used in con-
junction with:
Heat generator with Viessmann One Base
Or
Viessmann heat generator with Vitoconnect, e.g.
type OPTO2
Or
Vitoconnect, e.g. type OPTO2 without connection to
a Viessmann heat generator
The ViCare floor thermostat and a heat generator with
Viessmann One Base or Vitoconnect communicate via
low power radio.
Functions
The zones of the ViCare floor thermostat can be
included in energy efficient and convenient individual
room control.
Individual automatic time programs and manual
operation can also be used in individual room con-
trol.
The ViCare floor thermostat has a switching contact
for the heat demand or solenoid valve control.
In operation with the heat generator with Viessmann
One Base or Vitoconnect, e.g. type OPTO2, the heat
demand is automatically determined and optimally
controlled.
Note
At least 1 temperature value from a ViCare climate
sensor is required per heating circuit.
The ViCare floor thermostat has an internal frost pro-
tection function that prevents the pipes from freezing.
If the flow temperature falls below approx. 8 °C, the
ViCare floor thermostat opens until the flow tempera-
ture is reached again.
Includes a function to protect the heating circuits if
communication fails with the heat generator with
Viessmann One Base or Vitoconnect, e.g.
type OPTO2. The heat demand is activated and all
valves are controlled with 10 %. When communica-
tion is resumed, the valves return to normal mode.
The ViCare floor thermostat is compatible for opera-
tion with 230 V "normally closed" thermal actuators
(on site).
The ViCare floor thermostat is automatically deacti-
vated by the heat generator with Viessmann One
Base or Vitoconnect, e.g. type OPTO2, if the heat
generator also interrupts heating operation. E.g.
summer mode; only DHW mode is active.
To prevent the valves from sticking, the valve outputs
are opened for 8 minutes every 30 days after they
were last actuated.
The ViCare floor thermostat also functions as a low
power radio repeater.
Introductory information
Intended use (cont.)
6152540
Information
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann ViCare floor thermostat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann ViCare floor thermostat in the language / languages: English as an attachment in your email.

The manual is 3.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info